MPC based optimization using non-uniform sampling

3 visualizaciones (últimos 30 días)
RPatel
RPatel el 27 de Jul. de 2017
Comentada: Meeshawn Marathe el 2 de Ag. de 2017
Hello,
Discrete time optimization using Model predictive control usually takes samples at uniform intervals. In my case, due to the complexity of the operation, the solver/matlab is taking more computational time than I would like. Thus, I plan to use non-uniform sampling intervals. How can this be implemented in Matlab?
Best Regards,
Raj
  1 comentario
Meeshawn Marathe
Meeshawn Marathe el 2 de Ag. de 2017
Hi,
Did you try building your model in Simulink ? You can select variable-step discrete time solver in the configuration parameters.

Iniciar sesión para comentar.

Respuestas (0)

Categorías

Más información sobre Model Predictive Control Toolbox en Help Center y File Exchange.

Productos

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by