system identification procedure

1 visualización (últimos 30 días)
Mr Smart
Mr Smart el 16 de Oct. de 2012
Hello, anyone knows? How to make implementation or realization system identification procedure in matlab .Using simulink model(electric device model such as transfer function and integrator).From this model I can get experimental data(input and output).
  1 comentario
K E
K E el 19 de Oct. de 2012
In case it is helpful, there is a System Identification Toolbox for Matlab/Simulink that can be purchased.

Iniciar sesión para comentar.

Respuesta aceptada

Rajiv Singh
Rajiv Singh el 18 de Oct. de 2012
Have Simulink data available in MATLAB workspace as double vectors. In the GUI (ident) import time signals to load the data. Then you work from there. If you are estimating models in the command line, package the data into an iddata object:
data = iddata(y,u,Ts); % y = output; u = input; Ts = sample time
Then try various estimation commands, e.g:
model = tfest(data, 2); % second order transfer function
The logged data (y,u) must be equi-sampled. If not, interpolate them to a uniform time grid.
  2 comentarios
Amir Hejazi
Amir Hejazi el 27 de Abr. de 2013
what should we do if sample time was not constant?
Rajiv Singh
Rajiv Singh el 2 de Mayo de 2013
interpolate or log data from the Simulink model at constant time intervals. Most identification routines do not handle irregularly sampled data.

Iniciar sesión para comentar.

Más respuestas (0)