MATLAB Answers

pilot operated check valve to open only by pilot pressure x

8 views (last 30 days)
The pilot operated checkvalve provided in simscape fluids is operated by pressure at A or pilot pressure X or both, I wish to open the checkvalve only by pilot pressure . can anyone say is there anything I can do?
  2 Comments
murali manohar boopathy
murali manohar boopathy on 23 May 2021
actually my need is to close a checkvalve with a pilot pressure i.e even when there is craking pressure at A ,the pilot pressure should close the checkvalve but I found the checkvalve in simscape fluids opens with pilot pressure x so i chose to open the checkvalve when needed as i need to open and close 2 checkvalves but the checkvalve is in a way that it opens with both pressure at A and X like it's in double pilot checkvalve. I have attached a picture for your better understanding of my problem.

Sign in to comment.

Accepted Answer

Yifeng Tang
Yifeng Tang on 24 May 2021
Thanks for the details.
The pilot in this case is acting in the opposite direction as in the "Pilot-Operated Check Valve (IL)" block. It's equivalent to having a negative pilot ratio, but it won't allow you to set a negative value in the block.
Anyway, I think your best bet is to use a "Cartridge Valve Actuator (IL)" and a "Orifice (IL)" block.
The actuator allow you to open the check valve, with a physical signal, when the pressure combination is correct, and the Orifice will translate that signal to an opening that allows/blocks flow.