Respondida
Electrical Switch doesn't work
You are using an ideal current source set to 1 A. This means that whichever load you attach to it, it will maintain 1A. By open...

alrededor de 3 años hace | 1

| aceptada

Respondida
connection port bus for simulink
Connection Ports are different from regular signals which have a data type, can be vectorized with a mux or can be combined in a...

alrededor de 3 años hace | 0

Respondida
Protect a Simulink model but keep the possibility to modify it
You will need the Simulink Coder toolbox.

más de 3 años hace | 0

| aceptada

Respondida
How to load matrix variables as constant on Simulink?
Load the .mat file into the Base Workspace of MATLAB, and in Simulink use the From Workspace block to enter the variable name th...

más de 3 años hace | 0

| aceptada

Respondida
strcat not supported for code generation simulink
See documentation for the MATLAB Function block. There it is mentioned that: "In addition to language restrictions, the MATLAB F...

más de 3 años hace | 0

| aceptada

Respondida
Turn of slider switch automatically
Use a push button instead of a slider switch.

más de 3 años hace | 0

| aceptada

Respondida
Simulink custom (non rectangular) Block Shapes
I do not think it is possible to give subsystems an other shape than rectangular. It could conflict with the positioning of the ...

más de 3 años hace | 1

| aceptada

Respondida
Compilation of variant subsystem
In a Variant Subsystem, only the active subsystem will be compiled. Any other variants inside the Variant Subsystem will be igno...

más de 3 años hace | 0

| aceptada

Respondida
Data type work vector name must less than 31 characters long
Try to increase the setting 'Maximum identifier length' from 31 to 63. It can be found in the Configuration Parameters under 'Co...

más de 3 años hace | 0

| aceptada

Respondida
co-simulation within Simulink
I would put each subsystem inside an Enabled subsystem, and enable the second subsystem after the first subsystem had finished a...

más de 3 años hace | 1

| aceptada

Respondida
(Matlab) S-function - delayed output
To generate a PWM signal you need to sample much faster than only the switching frequency. You need the higher sample time to be...

más de 3 años hace | 0

Respondida
Single use switch in Simulink Real-Time
Enabled Subsystem?

más de 3 años hace | 0

Respondida
Temperature measurement on electrical circuit
When constructing your Simscape Electrical circuit, you will need to enable thermal ports of the relevant components which gener...

más de 3 años hace | 0

| aceptada

Respondida
How to control the CAN transmit Simulink block to send messages on command?
Put the CAN transmit block inside a Triggered subsystem and provide a Boolean with 'true' when you want to send the message. Al...

más de 3 años hace | 1

| aceptada

Respondida
How to get cyber attack models/blocks such as DOS attack, Man in the middle attack in Matlab/Simulink ?
Hi You may want to check the SimEvents package, it is designed to simulate communication and event structures. You can use it t...

más de 3 años hace | 0

Respondida
Best way to buffer vector data in Simulink for processing over a time window
Using Data Stores would indeed be a solution. However, the dimensions of your matrix increases over time, making it a variable ...

más de 3 años hace | 0

| aceptada

Respondida
What is the different between in "Monitor & Tune" and "Build, Deploy & Start" ?
Monitor & Tune means that you just read signals or write parameters to the connected target hardware. The application program ru...

más de 3 años hace | 0

Respondida
How to display the current value of a TagetPC-Signal in a numeric edit field (App Designer) and update the value automatically every timestep ?
Inside the myTimerFcn, write: app.AEditField.Value = getsignal(tg,'Path',1);

más de 3 años hace | 1

| aceptada

Respondida
How can I generate code for a Matlab function block in Simulink that contains a ''quadprog function''?
See the C/C++ Code Generation notes here. See an example for generating code with quadprog function here.

más de 3 años hace | 0

Respondida
How to display the current value of a TagetPC-Signal in a numeric edit field (App Designer) and update the value automatically every timestep ?
You need to create a timer object Attach a function call to the timer object Put your code to assign the realtime value to the...

más de 3 años hace | 0

Respondida
Interpretation of Simulink block warning
You have defined minimum and maximum values of a certain output or signal, and then probably created a vector of it using a Mux ...

más de 3 años hace | 1

Respondida
How to convert decimal into hexadecimal in "S function" Matlab ?
input = uint16(2748) output = zeros(2,1,'uint8'); output(1) = bitshift(input,-8); output(2) = bitand(input,255); output Hex...

más de 3 años hace | 0

Respondida
Cell arrays as top-level function outputs are not supported in MATLAB Function Block
The input and output of a MATLAB Function block in Simulink needs to be of a data type supported by Simulink. The data types sup...

más de 3 años hace | 0

| aceptada

Respondida
make a static const variable in generated code with Embedded Coder
In either the Model Workspace or a Data Dictionary linked to your model, create a Simulink.Parameter object and name it "MyNumbe...

más de 3 años hace | 0

Respondida
Deactivate a switch block once the threshold is achieved.
https://nl.mathworks.com/help/simulink/ug/enabled-subsystems.html

más de 3 años hace | 0

Respondida
Just want to display the scope's parameters for a period not from 0
Put the Scope block inside an Enabled Subsystem. Use the Digital Clock block to get the simulation time Use Relational Operato...

más de 3 años hace | 0

| aceptada

Respondida
How to run cyclic Simulink block once
Put it inside a Function-call Subsystem and use a function-call signal to trigger it Put it inside a Triggered Subsystem and to...

más de 3 años hace | 1

| aceptada

Respondida
How to input time series in a block parameter in Simulink?
https://nl.mathworks.com/help/simulink/slref/fromworkspace.html https://nl.mathworks.com/help/simulink/ug/load-data-using-the-f...

más de 3 años hace | 0

| aceptada

Respondida
How to stop if else condition after it executes only once.
Put your blocks inside an enabled subsystem, and use the outputs of your if-else block to disable the subsystem itself.

más de 3 años hace | 0

Cargar más