Respondida
How to control a fixed desired current in a 3-phase Interleaved Buck converter?
The output current looks stable. If you want to control the output current to a specific value, then a control algorithm should ...

9 meses hace | 0

Respondida
Battery temperature output not working in Simulink hybrid energy system model – need help integrating real-time thermal feedback for control logic
You can use Simscape Electrical or Simscape Battery for electro-thermal simulations. All battery blocks implemented in Sismcape ...

9 meses hace | 1

| aceptada

Respondida
PMLSM Controller Over Active
There are a few things you can try. Increase the inverter switching frequency (in the example 2 kHz is used) and reduce the fun...

9 meses hace | 0

| aceptada

Respondida
Which trick is used to adapt the PI gains calculated in per unit to work in Simulink if the input and output to the controller are all in per unit, but the plant is in physical units?
If you have a per unit controller, where input and output are in per unit. The only thing that is needed to go back to SI is the...

9 meses hace | 0

Respondida
Hello everyone, please help me with this error Error:Invalid
The problem is the way you pass the data in the From Workspace block. What you want is to have P as a time varying signal of dim...

9 meses hace | 0

Respondida
I don't understand what port 1 of the Two-Quadrant DC/DC Converter is and what should I connect it to?
This is a two quadrant DC-DC converter operating in first and second quadrant. It has two sets of DC connections. However, becau...

9 meses hace | 0

Respondida
simscape noise on scope display
This is not ho physical blocks are working. Think about a real-world system where you have a DC voltage source. To display the v...

9 meses hace | 0

Respondida
Matlab simulink components not conecting problem
It is not possible to directly connect Simscape blocks to Specialized Power Systems. It is better to use only one technology. Yo...

9 meses hace | 0

Respondida
In a paper, I saw that a 'Convert' block (not very clearly labeled) was used to connect an AND gate to a Voltage Measurement block.
Not sure what the question is. The Convert block in the image is a Data Type Conversion. The output of the AND block is boolean ...

9 meses hace | 0

Respondida
How to find the switching losses (reverse recovery losses) of the antiparallel diodes that are in a power converter?
Without a model is difficult to give specific advice. For IGBTs, it makes sense to see a decrease in switching losses when addin...

9 meses hace | 0

Respondida
How do i tune my STATCOM to fit my model?
Tuning the PI gains in the STATCOM can help with waveform ripples but may not address the core issue if both controllers are act...

9 meses hace | 0

Respondida
How does the PWM generator(3-level) block in Simulink work?
For linear operation of this block, the magnitude of Uref must be between −1 and +1 as per the documentation page. If the Uref ...

9 meses hace | 0

Respondida
How to find Thevenin Impedance at Bus 1 in a Two-Area System with Synchronous Machines?
Is it possible use the Impedance Measurement Tool. The Impedance Measurement Tool can be used in networks containing synchronous...

9 meses hace | 1

Respondida
Why do I get Fuel Cell stack - hydrogen partial pressure function calculation error?
Without the model we can not give a definitive answer. However, this points to a problem with the parameterization. Probably the...

9 meses hace | 0

Respondida
How to make a power divider control for battery supercapacitor work on the HESS PLTS Stand alone system?
In a battery-supercapacitor HESS, the time constant of the low-pass filter determines the frequency split between the battery an...

9 meses hace | 0

Respondida
PV array with DC/DC Buck Converter
Without the actual model we cannot point to any specific problem. It may be parameterization or design of MPPT. A good starting ...

9 meses hace | 0

Respondida
How to Model a DC Motor in State-Space with Load Torque Disturbance Rejection?
The state-space can be constructed as xdot=A.x+B.u+w, where w is the disturbance. If the disturbance is known a coordinate trans...

9 meses hace | 0

| aceptada

Respondida
issue on Machine losses Calculation and inverter loss calculation
First, the N-Channel IGBT block may be too complex for this kind of study. The N-Channel IGBT block is a high-fidelity represent...

9 meses hace | 0

Respondida
Dual Active Bridge Control model
Without a model, we can provide only general guidance. Some other resources that have not been mentioned and can be useful: htt...

9 meses hace | 0

Respondida
Why output results are coming 50 Nm when i checked pmsm block .actualy ipmsm machine model has to be generate 60 Nm for 300 phase current( id is -82 Amp, iq is 268 Amp).but i
Without a model is difficult to debug and point to a specific root cause. There can be a couple or things that can prevent the t...

9 meses hace | 0

Respondida
How can I integrate a phasor-based DFIG wind farm model with a discrete PV plant in a single power system simulation
If fast-switching dynamics are crucial for your study, consider converting the DFIG wind farm model to time domain. If your focu...

9 meses hace | 0

Respondida
simulink dc dc buck converter output not coming as desired
The issue concerns the fundamental sampling period. The timer period is set to 50 kHz (20 microseconds), and the sampling time m...

9 meses hace | 0

Respondida
Can't Visualize IGBT Overlap in 3-Phase Inverter Simulation (Simulink / Simscape)
In the case of IGBTs, it is possible to switch ON the opposite IGBT while the tail current is still flowing without causing dama...

9 meses hace | 1

| aceptada

Respondida
How to generate two PWM signals with 180° phase shift in Simulink (for controlling MOSFETs)
Simulink provides an efficient PWM block that can be used to generate an ideal pulse width modulated signal corresponding to inp...

9 meses hace | 0

Respondida
I AM TRYING TO CONTROL SYNCHRONOUS RELUCTANCE MOTOR USING FOC. (Rs) = 8 Ω, (Ld) = 1.2 H (Lq) = 0.1 H P= 2, (J) = 0.125 kg·m² , (B) = 0.009 IF THE SIMULATION DIAGRAM IS OK
It is not clear what the issue is but you can check out the in-product examples in Simscape Electrical as a starting point: htt...

9 meses hace | 0

Respondida
Converter (Three-Phase) block, Averaged Switch option, how to feed modulation waveform
There is an in-product example showing a comparison with differet levels of fidelity: converter with ideal switches, converter w...

9 meses hace | 1

| aceptada

Respondida
Split Phase Ungrounded System
In Simscape Electrical you can use an Electrical Reference block to simulate the connection to the ground. You can create artifi...

9 meses hace | 0

Respondida
How can I reduce Current spike in Hybrid CB?
The spike you observe after adding the snubber capacitor can be associated with the sudden discharge of energy stored in the cap...

9 meses hace | 0

Respondida
FM modulator circuit model using simscape simulink (2020b)
This indicates that the simulation cannot find a consistent set of initial values for the model's variables. This can be due to ...

9 meses hace | 0

Respondida
synchronous generator sudden load change effects
Without the model and all the parameters used in simulation it is not easy to point exactly to the root cause. However, this see...

9 meses hace | 0

Cargar más