Signal label mismatch
Diagnostic action to take when signal has multiple names through propagation
Model Configuration Pane: Diagnostics / Connectivity
Description
The Signal label mismatch configuration parameter determines the diagnostic action to take when a signal has different names as the signal propagates through blocks in a model. This diagnostic does not check for signal label mismatches on a virtual bus.
Settings
none (default) | warning | errornoneThe software takes no action.
warningThe software displays a warning.
errorThe software terminates the simulation and displays an error message.
Recommended Settings
| Application | Setting |
|---|---|
| Debugging | No impact |
| Traceability | No impact |
| Efficiency | No impact |
| Safety precaution | error |
Programmatic Use
Parameter:
SignalLabelMismatchMsg |
Value: 'none' | 'warning' | 'error' |
Default: 'none' |
Version History
Introduced in R2006b