Error loading Simulink with Simscape blocks
20 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Thilo Krause
el 13 de Mayo de 2020
Comentada: Thilo Krause
el 6 de Ag. de 2020
I have a problem opening Simulink Models that contain Simscape blocks. When I open the model the Matlab Command Window displays:
"Warning: Physical modeling domain definition file input.m not found. You will not be able simulate this model. Please close your model, then add the domain definition file to the MATLAB path and re-open your model.
Warning: Physical modeling domain definition file output.m not found. You will not be able simulate this model. Please close your model, then add the domain definition file to the MATLAB path and re-open your model."
The Simulink Diagnostic Viewer displays for every single Simscape block I used: "['Modell_Kreiselpumpe_Motor_Kreislauf_03032020/Ammonium-Water']: Parameter check for block 'Modell_Kreiselpumpe_Motor_Kreislauf_03032020/Ammonium-Water' failed.
Caused by:
- Too many output arguments.
Component:Simulink | Category:Model error"
I already tried to add the input.m resp. output.m file but I could not find it.
How can I solve this problem?
0 comentarios
Respuesta aceptada
Joel Van Sickel
el 5 de Ag. de 2020
Hello Thilo,
we've been seeing this error from a few people. The common recomendation is that it's an install issue. Please review this post to see how to due a thorough reinstall that should purge any issues. If you try this and it doesn't work, please let me know and we will get tech support involved.
Regards,
Joel
Más respuestas (0)
Ver también
Categorías
Más información sobre Foundation and Custom Domains en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!