Nota del editor: This file was selected as MATLAB Central Pick of the Week
These probes are for use with the Simscape multi-domain physical modeling tools (Simscape, Sim Driveline, SimHydraulics and SimElectronics). The ssc_Probes.m file calls the library file containing probes for viewing the through and across variable for each domain. The ssc_dc_motor.slx model file is an example of how to use. See Help block for additional usage notes.
To learn more about MathWorks Physical Modeling products go to: https://www.mathworks.com/solutions/physical-modeling.html
This toolbox was developed by Tom Egel from the [Consulting Services](http://www.mathworks.com/services/consulting/) group at MathWorks
Citar como
Tom Egel (2026). Simscape Probes (https://la.mathworks.com/matlabcentral/fileexchange/17969-simscape-probes), MATLAB Central File Exchange. Recuperado .
Compatibilidad con la versión de MATLAB
Compatibilidad con las plataformas
Windows macOS LinuxEtiquetas
Comunidades de usuarios
Descubra Live Editor
Cree scripts con código, salida y texto formateado en un documento ejecutable.
SimscapeProbes/
SimscapeProbes/Examples/
SimscapeProbes/Versions/
| Versión | Publicado | Notas de la versión | |
|---|---|---|---|
| 1.25.0.1 | Update for R2016b.
|
||
| 1.25.0.0 | Updated for 2015b. Fixed bug in CopyFcn callback when probe is place inside library block. |
||
| 1.24.0.0 | Updated for 14b |
||
| 1.23.0.0 | Updated for R2014a. Added a MATLAB script ssc_Probes.m that calls the appropriate version based on the MATLAB release. The Archive folder contains versions older than the current release of MATLAB. |
||
| 1.22.0.0 | One more update for R2013b that includes Probes for SimPowerSystems 3G domain in the Electrical library. |
||
| 1.21.0.0 | Updates for R2013b:
|
||
| 1.20.0.0 | Updated for 13a. Probes use MATLAB plots instead of Simulink Scopes. |
||
| 1.19.0.0 | Updated for R2013b. Replaced Simulink Scopes under mask with To Workspace blocks. OpenFcn callback plots workspave variables in MATLAB. |
||
| 1.18.0.0 | Updated for 12b |
||
| 1.17.0.0 | Fixed warning message bug found in R2012b pre-release. Updated current version (R2012a) and R2011b version in Archives directory to remove warning message when upgrading to R2012b. |
||
| 1.16.0.0 | Updated for R2012a |
||
| 1.15.0.0 | Updated for r2011a. Fixed minor bug (GroupSignals now only displays global signals) |
||
| 1.14.0.0 | Updated for R2010b. Added sl_customization menu to toggle Goto tag between local and global. Default is now local, per user request. |
||
| 1.13.0.0 | Assigned domain-specific default units to each probe and made unit visible when model is initialized using InifFcn callback. |
||
| 1.12.0.0 | Updates for r2010a include probes for Magnetic domain and sl_customizations for editing units and adding output port. See Info block for usage notes. |
||
| 1.11.0.0 | Updated for release 2010a. Added probes for Magnetic domain and sl_customization.m for changing units and adding output port (see Info block for details) |
||
| 1.5.0.0 | Changed release to 2009b |
||
| 1.3.0.0 | Added copyright notice |
||
| 1.2.0.0 | 1. Changed name to Simscape Probes.
|
||
| 1.1.0.0 | Updated to use more compact symbols for less clutter. Also added a physical signal scope. |
||
| 1.0.0.0 | Updated the "through" variable scopes (current, torque, etc...) so that the arrow correctly indicates positive flow when flipped or inverted. |
