A Five Stage Extraction Cascade with Backmixing and Control

PID control of a five stage extraction column with backmixing using Simulink.
2,5K descargas
Actualizado 27 oct 2004

Sin licencia

PID control over the exit raffinate composition (x5) of a five stages column is obtained by changing solvent flow rate (G). The set point is equal to 0.1. The model equations include backmixing effects. This problem is solved using Berkeley-Madonna in Chemical Engineering Dynamics, Ingham et al., Wiley-VCH, 2000. The program ExtractionCascade.m runs the simulink file ExtCont.mdl and plots the composition versus time of the five stages as well as the solvent flow rate versus time.

Citar como

Housam Binous (2024). A Five Stage Extraction Cascade with Backmixing and Control (https://www.mathworks.com/matlabcentral/fileexchange/6107-a-five-stage-extraction-cascade-with-backmixing-and-control), MATLAB Central File Exchange. Recuperado .

Compatibilidad con la versión de MATLAB
Se creó con R13
Compatible con cualquier versión
Compatibilidad con las plataformas
Windows macOS Linux
Categorías
Más información sobre Chemistry en Help Center y MATLAB Answers.