fgetl
(To be removed) Read line of text from instrument and discard terminator
This serial, Bluetooth, tcpip,
udp, visa, and gpib object
function will be removed in a future release. Use serialport, bluetooth,
tcpclient,
tcpserver,
udpport,
and visadev
object functions instead. For more information on updating your code, see Version History.
Syntax
tline = fgetl(obj)
[tline,count] = fgetl(obj)
[tline,count,msg] = fgetl(obj)
[tline,count,msg,datagramaddress,datagramport]
= fgetl(obj)
Arguments
| An interface object. |
| The text read from the instrument, excluding the terminator. |
| The number of values read, including the terminator. |
| A message indicating if the read operation was unsuccessful. |
| The datagram address. |
| The datagram port. |
Description
tline = fgetl(obj) reads one line of text
from the instrument connected to obj, and returns the data to
tline. The returned data does not include the terminator with
the text line. To include the terminator, use fgets.
[tline,count] = fgetl(obj) returns the
number of values read to count.
[tline,count,msg] = fgetl(obj) returns a
warning message to msg if the read operation was
unsuccessful.
[tline,count,msg,datagramaddress,datagramport]
= fgetl(obj)
returns the remote address and port from which the datagram originated. These values
are returned only if obj is a UDP object.
Examples
Create the GPIB object g, connect g to a
Tektronix® TDS 210 oscilloscope, configure g to complete read
operations when the End-Of-String character is read, and write the
*IDN? command with the fprintf function.
*IDN? instructs the scope to return identification
information.
g = gpib('ni',0,1);
fopen(g)
g.EOSMode = 'read';
fprintf(g,'*IDN?')Asynchronously read the identification information from the instrument.
readasync(g)
g.BytesAvailable
ans =
56Use fgetl to transfer the data from the input buffer to the
MATLAB® workspace, and discard the terminator.
idn = fgetl(g)
idn =
TEKTRONIX,TDS 210,0,CF:91.1CT FV:v1.16 TDS2CM:CMV:v1.04
length(idn)
ans =
55Disconnect g from the scope, and remove g
from memory and the workspace.
fclose(g) delete(g) clear g
Tips
Before you can read text from the instrument, it must be connected to
obj with the fopen function. A connected
interface object has a Status property value of
open. An error is returned if you attempt to perform a read
operation while obj is not connected to the instrument.
If msg is not included as an output argument and the read
operation was not successful, then a warning message is returned to the command
line.
The ValuesReceived property value is increased by the number
of values read — including the terminator — each time
fgetl is issued.
Note
You cannot use ASCII values larger than 127 characters. The function is limited to 127 binary characters.
Note
To get a list of options you can use on a function, press the Tab key after entering a function on the MATLAB command line. The list expands, and you can scroll to choose a property or value. For information about using this advanced tab completion feature, see Using Tab Completion for Functions.
Rules for Completing a Read Operation with fgetl
A read operation with fgetl blocks access to the
MATLAB Command Window until
The terminator is read. For serial port, TCPIP, UDP, and VISA-serial objects, the terminator is given by the
Terminatorproperty. Note that for UDP objects,DatagramTerminateModemust beoff.For all other interface objects except VISA-RSIB, the terminator is given by the
EOSCharCodeproperty.The EOI line is asserted (GPIB and VXI instruments only).
A datagram has been received (UDP objects only if
DatagramTerminateModeison).The time specified by the
Timeoutproperty passes.The input buffer is filled.
Note
You cannot use ASCII values larger than 127 characters. The function is limited to 127 binary characters.
More About the GPIB and VXI Terminator
The EOSCharCode property value is recognized only when
the EOSMode property is configured to
read or read&write. For example,
if EOSMode is configured to read and
EOSCharCode is configured to LF, then
one of the ways that the read operation terminates is when the line feed
character is received.
If EOSMode is none or
write, then there is no terminator defined for read
operations. In this case, fgetl will complete execution and
return control to the command line when another criterion, such as a timeout, is
met.