Rectangular Waveform
Rectangular pulse waveform
Libraries:
      Phased Array System Toolbox / 
      Detection
   
Description
The Rectangular Waveform block generates a rectangular pulse waveform with a specified pulse width and pulse repetition frequency (PRF). The block outputs an integral number of pulses or samples.
Ports
Input
Index to select the pulse repetition frequency (PRF), specified as a positive integer. The index selects the PRF from the predefined vector of values specified by the Pulse repetition frequency (Hz) parameter.
Example: 
                            4
Dependencies
To enable this port, select Enable PRF selection input.
Data Types: double
Frequency offset in Hz, specified as a scalar.
Example: 
            2e3
Dependencies
To enable this port, set Source of Frequency Offset to
                    Input port.
Data Types: double
Output
Pulse waveform samples, returned as a complex-valued vector.
Data Types: double
Pulse repetition frequency of current pulse, returned as a positive scalar.
Dependencies
To enable this port, set the Output signal
                                    format parameter to Pulses
                                and then select the Enable PRF output
                                parameter.
Data Types: double
Matched filter coefficients, returned as a vector or matrix.
Dependencies
To enable this port, select Enable Matched Filter Coefficients Output.
Data Types: double
Complex Number Support: Yes
Parameters
Sample rate of the output waveform, specified as a positive scalar. The ratio of Sample rate (Hz) to each element in the Pulse repetition frequency (Hz) vector must be an integer. This restriction is equivalent to requiring that the pulse repetition interval is an integral multiple of the sample interval.
Programmatic Use
| Block
                        Parameter: SampleRate | 
| Type:double | 
| Values:positive scalar | 
| Default: 1e6 | 
Method to set the pulse duration, specified as Pulse width
            or Duty cycle. When you set this parameter to
                Pulse width, the pulse duration is set using the
                Pulse width (s) parameter. When you set this parameter to
                Duty cycle, the pulse duration is computed from the
            values of the Pulse repetition frequency (Hz) and Duty
                Cycle parameters.
Programmatic Use
| Block
                        Parameter: DurationSpecification | 
| Type:string | 
| Values:string | 
| Default: 'Pulse
                    width' | 
The duration of each pulse, specified as a positive scalar. Set the product of Pulse width (s) and Pulse repetition frequency to be less than or equal to one. This restriction ensures that the pulse width is smaller than the pulse repetition interval. Units are in seconds.
Example: 300e-6
Dependencies
To enable this parameter, set the Method to specify pulse
                    duration parameter to Pulse width.
Programmatic Use
| Block
                        Parameter: PulseWidth | 
| Type:double | 
| Values:string | 
| Default: 50e-6 | 
Waveform duty cycle, specified as a scalar in the range [0,1].
Example: 0.7
Dependencies
To enable this parameter, set the Method to specify pulse duration
                parameter to Duty cycle.
Programmatic Use
| Block
                                                  Parameter: DutyCycle | 
| Type:double | 
| Values:positive scalar | 
| Default: 1e6 | 
Pulse repetition frequency, PRF, specified as a scalar or a row vector. Units are in Hz. The pulse repetition interval, PRI, is the inverse of the pulse repetition frequency, PRF. The value of Pulse repetition frequency (Hz) must satisfy these constraints:
- The product of Pulse width and Pulse repetition frequency (Hz) must be less than or equal to one. This condition expresses the requirement that the pulse width is less than one pulse repetition interval. For the phase-coded waveform, the pulse width is the product of the chip width and number of chips. 
- The ratio of sample rate to any element of Pulse repetition frequency must be an integer. This condition expresses the requirement that the number of samples in one pulse repetition interval is an integer. 
You can select the value of PRF by using block parameter settings alone or
      in conjunction with the input port, PRFIdx.
- When the Enable PRF selection input parameter is not selected, set the PRF using block parameters. - To implement a constant PRF, specify Pulse repetition frequency (Hz) as a positive scalar. 
- To implement a staggered PRF, specify Pulse repetition frequency (Hz) as a row vector with positive values. After the waveform reaches the last element of the vector, the process continues cyclically with the first element of the vector. When PRF is staggered, the time between successive output pulses cycles through the successive values of the PRF vector. 
 
- When the Enable PRF selection input parameter is selected, you can implement a selectable PRF by specifying Pulse repetition frequency (Hz) as a row vector with positive real-valued entries. But this time, when you execute the block, select a PRF by passing an index into the PRF vector into the - PRFIdxport.
In all cases, the number of output samples is fixed when you set the
        Output signal format to Samples. When you
      use a varying PRF and set Output signal format to
        Pulses, the number of output samples can vary.
Programmatic Use
| Block Parameter: PRF | 
| Type:double | 
| Values:positive scalar | 
| Default: 1e6 | 
Select this parameter to enable the PRFIdx port.
- When enabled, pass in an index into a vector of predefined PRFs. Set predefined PRFs using the Pulse repetition frequency (Hz) parameter. 
- When not enabled, the block cycles through the vector of PRFs specified by the Pulse repetition frequency (Hz) parameter. If Pulse repetition frequency (Hz) is a scalar, the PRF is constant. 
Programmatic Use
| Block
                        Parameter: PRFSelectionInputPort | 
| Type:logical | 
| Values:positive scalar | 
| Default: off | 
Source of frequency offset, specified as Property or
                                                  Input port. 
- When set to - Property, the offset is determined by the value of the Frequency Offset parameter.
- When set to - Input port, the offset is determined by the value of the FreqOffset port.
Programmatic Use
| Block
            Parameter: FrequencyOffsetSource | 
| Type:enum | 
| Values: Property,Input Port | 
| Default: Property | 
Frequency offset, specified as a scalar. Units are in Hz.
Example: 2e3
Dependencies
To enable this parameter set the Source of Frequency Offset
                parameter to Input port.
Programmatic Use
| Block
                        Parameter: FrequencyOffset | 
| Type:double | 
| Values: scalar | 
| Default: 0 | 
Source of simulation sample time, specified as Derive from waveform
                parameters or Inherit from Simulink engine.
            When set to Derive from waveform parameters, the block runs
            at a variable rate determined by the PRF of the selected waveform. The elapsed time is
            variable. When set to Inherit from Simulink engine,  the
            block runs at a fixed rate so the elapsed time is a constant.
Dependencies
To enable this parameter, select the Enable PRF selection input parameter.
Programmatic Use
| Block
                        Parameter: SimulationTimeSource | 
| Type:enum | 
| Values: Derive from waveform
                        parameters,Inherit from Simulink
                        engine | 
| Default: Derive from waveform
                        parameters | 
The format of the output signal, specified as Pulses or Samples.
If you set this parameter to Samples, the output of the block consists of multiple samples. The number of samples is the value of the Number of samples in output parameter.
If you set this parameter to Pulses, the output of the block consists of multiple pulses. The number of pulses is the value of the Number of pulses in output parameter.
Programmatic Use
| Block
                        Parameter: OutputFormat | 
| Type:enum | 
| Values: PulsesSamples | 
| Default: Pulses | 
Number of samples in the block output, specified as a positive integer.
Example: 1000
Dependencies
To enable this parameter, set the Output signal format
                parameter to Samples.
Programmatic Use
| Block
                        Parameter: NumSamples | 
| Type:double | 
| Values: positive
                        scalar | 
| Default: 100 | 
Data Types: double
Number of pulses in the block output, specified as a positive integer.
Example: 2
Dependencies
To enable this parameter, set the Output signal
                                        format parameter to
                                        Pulses.
Programmatic Use
| Block
                                                Parameter: NumPulses | 
| Type:double | 
| Values: positive
                                                scalar | 
| Default: 1 | 
Data Types: double
Select this parameter to enable the PRF output port.
Dependencies
To enable this parameter, set Output signal format to
                    Pulses.
Programmatic Use
| Block
                        Parameter: PRFOutputPort | 
| Type:enum | 
| Values: offon | 
| Default: off | 
Select this parameter to enable the Coeff output port.
Programmatic Use
| Block
                        Parameter: CoefficientOutputPort | 
| Type:enum | 
| Values: offon | 
| Default: off | 
Block simulation, specified as Interpreted Execution or
                Code Generation. If you want your block to use the
                MATLAB® interpreter, choose Interpreted Execution. If
            you want your block to run as compiled code, choose Code
                Generation. Compiled code requires time to compile but usually runs
            faster.
Interpreted execution is useful when you are developing and tuning a model. The block
            runs the underlying System object™ in MATLAB. You can change and execute your model quickly. When you are satisfied
            with your results, you can then run the block using Code
                Generation. Long simulations run faster with generated code than in
            interpreted execution. You can run repeated executions without recompiling, but if you
            change any block parameters, then the block automatically recompiles before
            execution.
This table shows how the Simulate using parameter affects the overall simulation behavior.
When the Simulink® model is in Accelerator mode, the block mode specified
            using Simulate using overrides the simulation mode.
Acceleration Modes
| Block Simulation | Simulation Behavior | ||
| Normal | Accelerator | Rapid Accelerator | |
| Interpreted Execution | The block executes using the MATLAB interpreter. | The block executes using the MATLAB interpreter. | Creates a standalone executable from the model. | 
| Code Generation | The block is compiled. | All blocks in the model are compiled. | |
For more information, see Choosing a Simulation Mode (Simulink).
Programmatic Use
| Block Parameter: SimulateUsing | 
| Type: enum | 
| Values: Interpreted Execution,Code
                        Generation | 
| Default: Interpreted Execution | 
Version History
Introduced in R2014b
See Also
MATLAB Command
You clicked a link that corresponds to this MATLAB command:
Run the command by entering it in the MATLAB Command Window. Web browsers do not support MATLAB commands.
Seleccione un país/idioma
Seleccione un país/idioma para obtener contenido traducido, si está disponible, y ver eventos y ofertas de productos y servicios locales. Según su ubicación geográfica, recomendamos que seleccione: .
También puede seleccionar uno de estos países/idiomas:
Cómo obtener el mejor rendimiento
Seleccione China (en idioma chino o inglés) para obtener el mejor rendimiento. Los sitios web de otros países no están optimizados para ser accedidos desde su ubicación geográfica.
América
- América Latina (Español)
- Canada (English)
- United States (English)
Europa
- Belgium (English)
- Denmark (English)
- Deutschland (Deutsch)
- España (Español)
- Finland (English)
- France (Français)
- Ireland (English)
- Italia (Italiano)
- Luxembourg (English)
- Netherlands (English)
- Norway (English)
- Österreich (Deutsch)
- Portugal (English)
- Sweden (English)
- Switzerland
- United Kingdom (English)