Model Advisor Check Issues for High-Integrity Systems
Metric ID
Metric ID:
mathworks.metrics.ModelAdvisorCheckIssues.hisl_do178
Description
Metric Type: Compliance
Family ID:
mathworks.metrics.ModelAdvisorCheckIssues
Use this metric to calculate number of issues reported by the subgroups of Model Advisor checks for High-Integrity Systems. This metric counts each Model Advisor check that produces a warning or failure. If a check contains links to blocks, this metric counts one issue for each linked block. Checks with links to the model are highlighted in the Simulink Editor. If a check does not contain links to blocks, this metric counts one issue. This metric is available with Simulink® Check™.
The slmetric.metric.AggregationMode
property setting is
Sum
.
Computation Details
The metric:
Runs on library models.
Analyzes content in masked subsystems.
If specified, analyzes the content of library-linked blocks or referenced models.
Analyzes content in Stateflow® objects.
Results
For this metric, instances of slmetric.metric.Result
provide the
following results:
Value
: Number of issues reported by the High-Integrity Systems checksAggregatedValue
: Number of issues reported by the High-Integrity Systems checks aggregated for a component and all of its subcomponents.Measures
: Not applicable.
For more information on the checks, see Model Advisor Checks for DO-178C/DO-331 Industry Standards.