Borrar filtros
Borrar filtros

Discharge of a costant volume chamber

1 visualización (últimos 30 días)
pietro
pietro el 30 de Nov. de 2013
Comentada: Abhishek Vats el 28 de Oct. de 2020
Hi all,
I'm modelling the discharge of a pressurized constant volume chamber at a specific temperature in the pneumatic domain. Here you can see the model:
The model works fine in charging, but not in discharging; the same the flow rate in charging is much higher than in discharging with the same valve area and pressure difference. Here you can see the pressure trend in discharging top and in charging bottom with the same pressure difference:
Charging:
Discharging:
As you can see in charging the max flow rate is around 2e-3 kg/s instead in discarghing is around -7e-6 kg/s (the pressure difference is the opposite than in the charging simulation) even if the valve area and pressure difference is the same. Should them be the same?
I'm attaching the model.
Any suggestion is appreciated.
Thanks
Thanks
  2 comentarios
dpb
dpb el 30 de Nov. de 2013
I don't have Simulink and my eyes can't read the graphics but just a question that comes to mind...is the driving pressure really the same in discharge as in charge? It strikes me that there may be an external "push" that's there from the air source that isn't when discharging so that what you think is the same dP really isn't (except instantaneously at the initiation of discharge, perhaps).
I don't know that has anything whatever to do with the problem; just a thought reading the problem description...
pietro
pietro el 2 de Dic. de 2013
Hi,
thanks for your reply. With such easy model I don't see any external "push".
Here you can see the model without the pressure source subsystem to make you to understand what there is inside it.
Here again the result plots with a better quality:
At the discharge the initial pressure of the chamber was 0.01 bar and at the outlet was 2.51 bar because I can't set a chamber pressure of 0 bar. As you can see in the charge the chamber pressure quickly reaches the outlet pressure. I checked with pressure sensor if the pressure difference was the same and it is. This issue is driving me crazy.

Iniciar sesión para comentar.

Respuestas (1)

pietro
pietro el 5 de Dic. de 2013
Hi,
solved the problem....it was due to a temperature difference between the chamber and the line. Thanks for your help
  1 comentario
Abhishek Vats
Abhishek Vats el 28 de Oct. de 2020
Hi , i download this circuit but its not working can you help me to understand this and share the correct circuit @abhishekvats_rajbir@srmuniv.edu.in sir.

Iniciar sesión para comentar.

Categorías

Más información sobre Elements en Help Center y File Exchange.

Etiquetas

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by