How to change Simulink constant block value to a constant variable?
121 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Sumin
el 10 de Jun. de 2014
Comentada: sherif Gad
el 12 de Nov. de 2021
Hello,
I'm trying to find a way to set constant value in constant block in Simulink to a constant variable. Namely, I want to set the constant value to g*c/3. g and c values are optimized by fmincon and determined.
In MATLAB, I tried to write something like
>> set_param([simfilename '/Constant2'],'Constant value',num2str(gc/3));
The constant block in Simulink has been named as "Constant2".
What I'm trying to achieve is to have this constant block output different numerical outputs according to g and c values determined by fmincon.
Thank you.
0 comentarios
Respuesta aceptada
Kaustubha Govind
el 12 de Jun. de 2014
set_param([simfilename '/Constant2'],'Value', num2str(gc/3));