custom phase changing material does not release heat.
    4 visualizaciones (últimos 30 días)
  
       Mostrar comentarios más antiguos
    
Problem:
When I adjust the latent heat, there's no change in the temperature curve of the XPS material. I anticipate a stable temperature, ranging between 305K and 320K. So the problem is that the material does not release the absorbed heat. 
  equations
        assert(Cps > 0 && Cpl > 0)
        assert(T > 0, 'Temperature must be greater than absolute zero')
        T == M.T;
        if T >= Tmelt_start && T <= Tmelt_end
            phaseChangeRate == {0.001, '1/s'};
        else
            phaseChangeRate == {0, '1/s'};
        end
        if phase < 1 && phase > 0
            Q == m * Cps * T.der + m * L * phaseChangeRate;
            phase.der == phaseChangeRate;
        else
            Q == m * Cpl * T.der;
            phase.der == {0, '1/s'};
        end
    end

explanation of the full code:
This code describes a thermal component that models internal energy storage in a thermal network. Here's a breakdown of the main parts of this code:
1. **Nodes**: These are points where other components can connect. Two thermal nodes are defined: `M` (top) and `N` (bottom).
2. **Inputs**: These values can be supplied from outside. `Mdot` represents the mass flow rate (in kg/s) and `T_in` is the input temperature (in Kelvin).
3. **Parameters**: These values determine the behavior of the component. They include:
   - `mass_type`: Type of mass (constant or variable).
   - `mass`: The mass of the thermal component.
   - `Cps` and `Cpl`: Specific heat capacity for solid and liquid, respectively.
   - `Tmelt_start` and `Tmelt_end`: The temperature range where the material starts melting and stops melting.
   - `L`: Specific latent heat.
   - `mass_min`: Minimum mass.
   - `num_ports`: The number of graphical ports.
4. **Annotations**: These are metadata that provide additional information about the component or dictate how it is displayed in a GUI. Here, it is primarily used to indicate which parameters can be modified externally and to define the component's icon.
5. **Variables**: These represent the internal states of the component. They include:
   - `m`: The mass.
   - `T`: The temperature.
   - `phase`: The phase (0 for solid, 1 for liquid, and values in between for a mixed phase).
   - `phaseChangeRate`: The rate of phase change.
   - `Q`: Heat flow rate.
6. **Branches**: These are connections between different parts of the network. Here, the heat flow `Q` from node `M` to another part of the network is defined.
7. **Equations**: These describe the mathematical relationships between the different variables and parameters. They include:
   - Relationships between `T`, `Q`, `m`, and other variables, especially around phase change.
   - Constraints on certain values (like that `Cps`, `Cpl`, and `T` must be positive).
8. **Connections**: These are the actual connections between the different nodes within the component. Here, node `M` is connected to node `N`.
The essence of this component is that it models a thermal mass that can store and release energy. It also accounts for phase changes, meaning it can melt or solidify within a certain temperature range.
component derdecomponent
    % Thermal Mass
    % This block models internal energy storage in a thermal network.
    nodes
        M = foundation.thermal.thermal; % :top
    end
    inputs(ExternalAccess = none)
        Mdot = {0,   'kg/s'};    % Mdot:bottom
        T_in = {300, 'K'};       % Tin:bottom
    end
    nodes(ExternalAccess = none)
        N = foundation.thermal.thermal; % :bottom
    end
    parameters
        mass_type = foundation.enum.constant_variable.constant; % Mass type
    end
    parameters (ExternalAccess = none)
        mass      = {1,   'kg'};    % Mass
    end
    parameters
        Cps = {200, 'J/(kg*K)'}; % Specific heat solid
        Cpl = {1000, 'J/(kg*K)'}; % Specific heat liquid
        Tmelt_start = {320, 'K'}; % Start Melting Temperature
        Tmelt_end = {305, 'K'}; % End Melting Temperature
        L = {100, 'J/(kg)'}; % Specific Latent Heat
    end
    parameters (ExternalAccess = none)
        mass_min  = {1e-6,'kg'};    % Minimum mass
    end
    parameters 
        num_ports = foundation.enum.numPorts2.one;     % Number of graphical ports
    end
    if num_ports == 2
        annotations
            N : ExternalAccess=modify
        end
        if mass_type == foundation.enum.constant_variable.constant
            annotations
                % Icon = 'mass2.svg'
            end
        else
            annotations
                % Icon = 'mass4.svg'
            end
        end
    else
        if mass_type == foundation.enum.constant_variable.variable
            annotations
                % Icon = 'mass3.svg'
            end
        end 
    end
    if mass_type == foundation.enum.constant_variable.constant
        annotations
            mass : ExternalAccess=modify
        end
        equations
            m == {1,'kg'};
        end
    else
        annotations
            [Mdot, T_in, m, mass_min] : ExternalAccess=modify
        end
        equations
            assert(mass_min > 0)
        end
    end
    variables (ExternalAccess=none)
        m = {value = {1,'kg'}, priority=priority.high}; % Mass
    end
    variables
        T = {value = {300, 'K'}, priority = priority.high}; % Temperature
        phase = {value = {0, '1'}, priority = priority.high}; % Phase
        phaseChangeRate = {0, '1/s'}; % Rate of phase change
    end
    variables (Access=private)
        Q = {0, 'W'}; % Heat flow rate
    end
    branches
        Q : M.Q -> *;
    end
    equations
        assert(Cps > 0 && Cpl > 0)
        assert(T > 0, 'Temperature must be greater than absolute zero')
        T == M.T;
        if T >= Tmelt_start && T <= Tmelt_end
            phaseChangeRate == {0.001, '1/s'};
        else
            phaseChangeRate == {0, '1/s'};
        end
        if phase < 1 && phase > 0
            Q == m * Cps * T.der + m * L * phaseChangeRate;
            phase.der == phaseChangeRate;
        else
            Q == m * Cpl * T.der;
            phase.der == {0, '1/s'};
        end
    end
    connections
        connect(M,N)
    end
end
0 comentarios
Respuestas (1)
  Shishir Reddy
      
 el 23 de Ag. de 2024
        Hi Berkay
The issue seems to be related to the logic in the phase change model. 
‘Tmelt_start’ has been set to 320K and ‘Tmelt_end’is set to 305K. This is inverted, typically the melting process starts at a lower temperature and ends at high temperature. So, the values must be swapped.
Tmelt_start = {305, 'K'};
Tmelt_end = {320, 'K'};
In calculating ‘’phaseChangeRate‘ - (T >= Tmelt_start && T <= Tmelt_end)’ – This condition only checks if the temperature T is within the range where phase change can occur. But it should also be ensured that ‘phaseChangeRate’ should be applied only when the material is neither fully solid (phase == 0) nor fully liquid (phase == 1).
For example, consider a material that starts melting at 305 K and finishes at 320 K. If the temperature is 310 K, it is within the range, but if ‘phase’== 0’ or ‘phase == 1’, the material is not currently undergoing a phase change. Conversely, if ‘phase’ is between 0 and 1 but the temperature is outside 305-320 K, the phase change should not be active.
So, the code should be modified as follows.
if T >= Tmelt_start && T <= Tmelt_end && phase < 1 && phase > 0
    phaseChangeRate == {0.001, '1/s'};
else
    phaseChangeRate == {0, '1/s'};
end
I hope this helps.
0 comentarios
Ver también
Categorías
				Más información sobre Thermal Liquid Library en Help Center y File Exchange.
			
	Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!