How to make static variable in Simulink

34 visualizaciones (últimos 30 días)
Benjamin
Benjamin el 28 de Feb. de 2011
I have several identical simulink models, where only the parameters vary:
Simulink block 1 uses the variables x.a{1}, x.b{1}, x.c{1} etc.
Simulink block 2 uses the variables x.1{2}, x.b{2}, x.c{2} etc
... up to Simulink block n using x.a{n} etc. The constants are used in gains, sums state space models etc.
How can i avoid hard coding the above numbers 1 through n in each and every block? I.e. i want Simulink block 1 to only contain the number 1 one time.
Hope this makes sense :)
Benjamin

Respuesta aceptada

Sebastian
Sebastian el 28 de Feb. de 2011
You could use a masked subsystem and just have the block instance number n as a parameter. Then in the mask initialization function you can access the structure fields and map to some local variables.
  3 comentarios
Paulo Silva
Paulo Silva el 28 de Feb. de 2011
Unless a variable is defined in a mask that variable will be the same one that's on your workspace, when your start the simulation simulink gets the values for each variable (for example one Constant block with the variable MyVar in the Value).
Benjamin
Benjamin el 12 de Mzo. de 2011
Ok thanks that makes sense :)