Why is bootci giving different interval than prctile?
Mostrar comentarios más antiguos
I was trying to show confidence interval on a histogram with the following code.
n = 10e3;
data = randn(n,1);
alpha = 0.05;
nboot = 10e3;
mu = mean(data);
[ci,bootstat] = bootci(nboot,{@mean,data},"Alpha",alpha,"Type","percentile");
bootstat = bootstat-mu;
ci = ci-mu;
figure
histogram(bootstat,"Normalization","cdf")
hold on
yline(alpha, "Color","#D95319")
yline(1-alpha, "Color","#D95319")
xline(ci(1), "Color","#D95319")
xline(ci(2), "Color","#D95319")

The computed confidence interval does not aligne with the "cdf" histogram. But when I compute the interval using the following function, then it aligns as expected.
ci = prctile(bootstat, [alpha*100,(1-alpha)*100]);

Does anybody know, why is that the case?
Respuesta aceptada
Más respuestas (1)
the cyclist
el 16 de Dic. de 2024
Because your prctile calculation should be
ci = prctile(bootstat, [(alpha/2)*100,(1-(alpha/2))*100]);
Categorías
Más información sobre Resampling Techniques en Centro de ayuda y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!