How to integrate a control system by ode45 with PID control input ?
22 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Chuguang Pan
el 20 de Nov. de 2025
Comentada: Chuguang Pan
el 21 de Nov. de 2025
I want to simulate a control system using ode45 function. The system model can be expressed as
, where the control input u is the PID control which can be expressed as
. The
is the desired state. My question is how to integrate the error in the ode model as illustrated in the following code example, since we only obtain the current time state X when the f function is called
function dX = f(t,X,P)
% ...
% ...
u = P.Kp * (P.Xd - X) + P.Ki * (P.Xd - X) + ... ; % How to integrate the error Xd - X ?
end
0 comentarios
Respuesta aceptada
Sam Chak
el 20 de Nov. de 2025
Perhaps you can try this approach.
G = tf(1, [1, 0, 0]);
opt = pidtuneOptions('DesignFocus', 'disturbance-rejection');
wc = 5;
C = pidtune(G, 'PID', wc, opt);
% Parameters
P.Xd = 3; % desired state for X(1)
P.Kp = C.Kp; % proportional gain
P.Ki = C.Ki; % integral gain
P.Kd = C.Kd; % derivative gain
% ODE function
function dX = f(t, X, P)
% error
e = P.Xd - X(1);
% PID controller
u = P.Kp*e + P.Ki*X(3) - P.Kd*X(2);
% disturbance
d = 1;
% original 2nd-order system
dX(1) = X(2);
dX(2) = d + u;
% X(3) is ∫ e dt
dX(3) = e;
% system dynamics
dX = [dX(1)
dX(2)
dX(3)];
end
% Solve and plot
[t, X] = ode45(@(t, X) f(t, X, P), [0, 10], zeros(3, 1));
plot(t, X(:,1)), grid on
title('Time response for state x_{1}')
xlabel('t')
ylabel('x_{1}')
Más respuestas (1)
Torsten
el 20 de Nov. de 2025
Add a second differential equation
dV/dt = P.Xd - X
with initial condition
V(0) = 0
Then
V(t) = integral_{0}^{t} (P.Xd - X) dt
0 comentarios
Ver también
Categorías
Más información sobre Ordinary Differential Equations en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!