Borrar filtros
Borrar filtros

Reset Initial Conditions of level 1 S-function states

1 visualización (últimos 30 días)
Remus
Remus el 16 de Jun. de 2015
Respondida: Andrew Schenk el 17 de Jun. de 2015
Hello.
Is it possible to reset the initial conditions of the states of a continuous time level-1 s-fun? Usually the states I.C. are set by mdlInitializeSizes() function call at the beginning of the simulation. But what if in the middle of the sim I want to reset the IC?
Thanks.

Respuestas (1)

Andrew Schenk
Andrew Schenk el 17 de Jun. de 2015
There are two ways to do this. You can either:
  1. Add an extra input to the S-function and write a conditional statement to reset the states when the extra input value changes.
  2. Place the S-function inside of an enabled / triggered subsystem and set the "Output when disabled" to "reset" - this will call mdlInitialize every time the subsystem is disabled.

Categorías

Más información sobre Block and Blockset Authoring en Help Center y File Exchange.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by