Simulink - Rate Transition

6 visualizaciones (últimos 30 días)
JOKY JOKE
JOKY JOKE el 7 de Dic. de 2011
Hi,
I want to use Rate Transitions in my Simulink System. I am using a Fixed-Step + Discrete Solver with a discrete step-size. If I want to implement different tasks, for example, Task 1 with a sample time of 10 ms and Task 2 with a sample time of 1 ms. Does the fixed-step size in the Configuration Parameters has to be the smallest sample time, i.e. 1 ms or is it also possible to run the whole system with 10 ms and just a few calculations with the fast sample time of 1 ms?
Thank you

Respuesta aceptada

Kaustubha Govind
Kaustubha Govind el 7 de Dic. de 2011
I think you should set your solver step size to 1ms. Simulink will determine that the blocks in Task1 have to be run only every 10ms and invoke them accordingly.

Más respuestas (1)

Suneesh
Suneesh el 7 de Dic. de 2011
The step size in configuration parameters has to be the smallest (fundamental) step size. Other blocks can have sample times that are integer multiples of the fundamental. 'Rate Transition' block is used to connect parts of the model running at different rates

Categorías

Más información sobre Multicore Processor Targets en Help Center y File Exchange.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by