How do I know what is the problem with "stereoParams" output from Stereo Calibration Tool ? The output of rectifyStereoImages are black images
1 visualización (últimos 30 días)
Mostrar comentarios más antiguos
I am running the calibration tool to get the parameters, with a mean error of less than a pixel. But when I use these parameters to "rectifyStereoImages" function. the rectified images are just generally black images. I am not sure why this happening, It does not happen when I use stereoParams from an example. What is wrong with my "stereoParams"?
if true
frameLeft = imread('cal_L_2.png');
frameRight = imread('cal_R_2.png');
imshow(frameLeft);
[frameLeftRect, frameRightRect] = rectifyStereoImages(frameLeft, frameRight, stereoParams);
figure;
imshow(stereoAnaglyph(frameLeftRect, frameRightRect));
title('Rectified Video Frames');
end
0 comentarios
Respuestas (1)
Don Zheng
el 17 de Jul. de 2017
Make sure that 'frameLeftRect' and 'frameRightRect' are expected rectified images and 'imshow'able separately. Also, make sure there are enough distinct key points other than the calibration grids for pattern matching.
Also worth trying other example images from the documentation to identify at which step things go wrong.
3 comentarios
Don Zheng
el 18 de Jul. de 2017
Were you getting cropped images for 'frameLeftRect' and 'frameRightRect' without 'full' 'Output'?