Model_X has multiple sample times error
55 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
ricard molins
el 20 de Feb. de 2019
Respondida: dc
el 23 de Abr. de 2023
I am getting the following error
'MyTopLevelModel/SubsystemA/Model' has multiple sample times. Only constant (inf) or inherited (-1) sample times are allowed in function call subsystem 'MyTopLevelModel/SubsystemA'.
More info of my setup
SubsystemA has a function call which has a trigger port connected to a port set as "output function call with sample time of 0.001. All my other blocks have sample time -1 (inheritet).
If I go to the model explorer the compiled sample time are not [-1 0] some of the have set the [0.001 0]
Any idea what could be causing this error ?
3 comentarios
Arvind Sathyanarayanan
el 20 de Feb. de 2019
To identify which block(s) have a different sample time goto Display ->Sample TImes -> Colors.
Respuesta aceptada
Más respuestas (1)
dc
el 23 de Abr. de 2023
it is very puzzle;you need configure the function call ‘s sample time in the runnable/system;i mean the display of f() . do not configure reference
0 comentarios