I am getting the following error
'MyTopLevelModel/SubsystemA/Model' has multiple sample times. Only constant (inf) or inherited (-1) sample times are allowed in function call subsystem 'MyTopLevelModel/SubsystemA'.
More info of my setup
SubsystemA has a function call which has a trigger port connected to a port set as "output function call with sample time of 0.001. All my other blocks have sample time -1 (inheritet).
If I go to the model explorer the compiled sample time are not [-1 0] some of the have set the [0.001 0]
Any idea what could be causing this error ?
  3 comentarios
ricard molins
ricard molins el 20 de Feb. de 2019
Can't share the model. Thats the reason I am asking for guidance of where could the potential error be and not a specific solution to my issue.
Arvind Sathyanarayanan
Arvind Sathyanarayanan el 20 de Feb. de 2019
To identify which block(s) have a different sample time goto Display ->Sample TImes -> Colors.

Iniciar sesión para comentar.

Respuesta aceptada

ricard molins
ricard molins el 22 de Feb. de 2019
The problem was that a configuration reference had a time step set to 0.01. This time step was transformed into a CompiledTimeStep and therefore it set a CompiledTimeStep different to -1 or inf. Setting the time step to auto solved the issue.

Más respuestas (1)

dc
dc el 23 de Abr. de 2023
it is very puzzle;you need configure the function call ‘s sample time in the runnable/system;i mean the display of f() . do not configure reference