why does sine curve not properly plotted in simulink

80 visualizaciones (últimos 30 días)
Shivank Anchal
Shivank Anchal el 20 de Jun. de 2019
Comentada: Aditya Yadav el 1 de Jun. de 2021
sine.PNG
  1 comentario
Shivank Anchal
Shivank Anchal el 20 de Jun. de 2019
when the stop time is 10 seconds,it gives a proper sine curve, but when I increase the time it gives the sine graph unlike sine graph.Pls help me with this, why is this happening?

Iniciar sesión para comentar.

Respuesta aceptada

Shubham Gupta
Shubham Gupta el 21 de Jun. de 2019
I reckon that you are using variable time step so when you increase your time, time step also increases. So, the curve is not as smooth as you have expected. To solve this use fixed time step and keep it small to get smoother curve.
Go to File->Simulink Preferences->Under Sover option, choose "fixed step" type and then choose fixed time step like 1ms
  4 comentarios
Shubham Gupta
Shubham Gupta el 27 de Jun. de 2019
I am not if this info is still relevant but I reckon you are using so you might have to access solver options using different method. couple of methods that might work are:
Method 1 :
If you can see a gear type button in the simulink's toolbar, you can use that to change the sample time
Method 2 :
Go to Simulink->Configuration Parameter
Method 3 :
Press Ctrl+F to open Configuration Parameters directly
I hope it works !
Aditya Yadav
Aditya Yadav el 1 de Jun. de 2021
Really helpful..Thanks