Why the angular velocities measured by bushing joint and transform sensor are different

2 visualizaciones (últimos 30 días)
I built a model of parallel manipulators using simMechanics, but I found that the angular velocities of the moving platform measured by bushing joint and transform sensor are different, so why?
untitled.jpg
  2 comentarios
Devineni Aslesha
Devineni Aslesha el 29 de Ag. de 2019
In the given plot, I would like to know which plot corresponds to bushing joint and transform sensor. Also, would like to know how the angular velocity is measured. Is it the magnitude of angular velocity or the angular velocity in a particular direction?
Chong Zhao
Chong Zhao el 6 de Sept. de 2019
Thank you for your answer. I was measuring the angular velocities in a X/Y/Z direction, as shown in the figure below. But the wx/wy/wz in the transform sensor and wx/wy/wz in the bushing joint were different.
sensor.jpg

Iniciar sesión para comentar.

Respuesta aceptada

Harshal Upadhyay
Harshal Upadhyay el 13 de Sept. de 2019
Bushing joint seems to be using Euler parametrization(refer to the Joint Transformation Sequence). https://www.mathworks.com/help/physmod/sm/ref/bushingjoint.html