This model is configured for concurrent execution and has modeling constraints. Input port 1 of xx block must be contiguous. what's that mean?
25 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Hi everyone, I want to use concurrent execution on a motor control model to use multi-core parallel computing to speed up the simulation, but when I configured the various sampling rate programs as atomic subsystems, the check still has the following problems, please tell me what I should do to solve this problem, I have no idea now.
1 comentario
Qiancheng Zhou
el 24 de Ag. de 2022
You can add a 'Signal Conversion' block before outport to aviod this issue.
Respuestas (1)
Qing Liu
el 9 de Mayo de 2022
Hi, Xu Liu,
When I mux signals in a subsystem, and demux them in another concurrent subsystem, I get the this error. But I am not sure this is the only reason for the error of this type.
1 comentario
Qiancheng Zhou
el 24 de Ag. de 2022
You can add a 'Signal Conversion' block before outport to aviod this issue.