Stator Flux Estimation of Induction Motor in real time

1 visualización (últimos 30 días)
Hi,
I am using TMS320F28379D LAUNCHPad for implementation of induction motor control and code is generated from MATLAB2019b.
for this i have to estimation of stator an rotor flux in alpha,beta frame.
i am using Eq.
but output of integration of voltage quantity is not in sin shape and it is continuously decreasing in nature however input quantity is sinusoidal in nature.
how i can debug this kind of problem?
please provide any solutions for this?
Thanks in advanced

Respuesta aceptada

Dr. Pemendra Kumar Pardhi
Dr. Pemendra Kumar Pardhi el 11 de Jun. de 2021
If any one suffer with above problems It is occurring due to DC ofset in sensed quantity ( it is due to sensor's inherently properties/scaling error) Above problem is mitigate by dc ofset mitigation strategies

Más respuestas (0)

Categorías

Más información sobre Specialized Power Systems en Help Center y File Exchange.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by