If any one suffer with above problems It is occurring due to DC ofset in sensed quantity ( it is due to sensor's inherently properties/scaling error) Above problem is mitigate by dc ofset mitigation strategies
Stator Flux Estimation of Induction Motor in real time
1 visualización (últimos 30 días)
Mostrar comentarios más antiguos
Dr. Pemendra Kumar Pardhi
el 31 de Dic. de 2020
Respondida: Dr. Pemendra Kumar Pardhi
el 11 de Jun. de 2021
Hi,
I am using TMS320F28379D LAUNCHPad for implementation of induction motor control and code is generated from MATLAB2019b.
for this i have to estimation of stator an rotor flux in alpha,beta frame.
i am using Eq.
but output of integration of voltage quantity is not in sin shape and it is continuously decreasing in nature however input quantity is sinusoidal in nature.
how i can debug this kind of problem?
please provide any solutions for this?
Thanks in advanced