stateflow
3 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Hi all, Here I am using "after(0.025, sec)" in statechart for generating pulse, but when it wached on scope,its generating at 0.03, why is the difference. Can any help me how to make exact at 0.025.
3 comentarios
Respuesta aceptada
Gerd
el 17 de Jun. de 2011
Hi Murali,
using a sample time of 0.01s for your model lets you only generate pulses with a multiple of the basic sample time(0.01 / 0.02 / 0.03) If you want to generate a pulse of 0.025 you have to increase your sample time to e.g. 0.001s
Gerd
3 comentarios
Gerd
el 17 de Jun. de 2011
Murali,
please open the model.
Double click on the upper chart "With absolute Time".
Change the transition to "After(0.025,sec)".
Hit Ctrl+E. Change the fundamental sample time to 0.001.
Open the scope and open Parameter pane. Go to "History".
Deselect Limit data points to last.
Run the model and observe the result.
I did these steps and the result is Ok
Más respuestas (0)
Ver también
Categorías
Más información sobre Complex Logic en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!