PWM converter delay

Pulse width modulated (PWM) converters introduce a delay of 0.5*T. The delay should be taken into account when controller is tuned.
207 descargas
Actualizado 12 Jun 2020

Ver licencia

Does a delay introduced by the PWM converter depend on the modulation scheme used (unipolar vs. bipolar, continuous vs. discontinuous)? No.
The only reason for this delay is that the modulator fed by the sampled control signal has to use ZOH (zero-order hold) in order to compare this signal with the triangular carrier signal. The delay related to ZOH is equal to T/2. A digital controller introduces a delay of T. Therefore, if no other significant delays are present in the measurement/acquisition/conditioning/filtering interface, the delay of 1.5*T should be used to calculate current controller gains. The example demonstrates such a procedure.

Citar como

Bartlomiej Ufnalski (2024). PWM converter delay (https://www.mathworks.com/matlabcentral/fileexchange/76884-pwm-converter-delay), MATLAB Central File Exchange. Recuperado .

Compatibilidad con la versión de MATLAB
Se creó con R2019b
Compatible con cualquier versión
Compatibilidad con las plataformas
Windows macOS Linux

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!
Versión Publicado Notas de la versión
1.0.0