Pregunta


Simscape IL actuator connecting port A and B using valve
The directional valve 304 is set to connect port 2 and 4 (port A and B of the piston). Now, when applying a force on the piston ...

7 meses hace | 0 respuestas | 0

0

respuestas

Respondida
localtime not defined error when generating C++ code in Simulink using TE1400
Same as in my other question, the solution had nothing to do with the errors that I posted above. The problem was actually the c...

8 meses hace | 0

| aceptada

Respondida
Zero division when generating Simscape Code using Beckhoff TE1400
The solution to this problem had nothing to do with the model itself. I still dont understand why it worked without the capacito...

8 meses hace | 0

| aceptada

Pregunta


localtime not defined error when generating C++ code in Simulink using TE1400
I am using TwinCAT Target for Simulink TE1400 to generate C++ code from a simple Simscape model. When generating Code I get a fe...

8 meses hace | 1 respuesta | 0

1

respuesta

Pregunta


Zero division when generating Simscape Code using Beckhoff TE1400
I am using the TwinCAT Target for Simulink TE1400 to generate Code from a Simscape model. I have all the necessary licenses and ...

8 meses hace | 1 respuesta | 0

1

respuesta

Respondida
Simscape fixed displacement pump pressure gain wrong?
Alright I figured it out. I misunderstood the nominal pressure gain parameter. I thought that it describes the delta p of the pu...

8 meses hace | 0

| aceptada

Pregunta


Simscape fixed displacement pump pressure gain wrong?
When working with the fixed displacement pump block in Matlab Simscape I noticed that the nominal pressure gain parameter is not...

8 meses hace | 2 respuestas | 0

2

respuestas

Pregunta


Simscape piston moves without pressure difference
Hello, I noticed when adding a mass block to the piston rod, the pressure difference between chamber A and B seems to be zero. ...

9 meses hace | 1 respuesta | 0

1

respuesta

Respondida
Transient initialization failed to converge using Simscape piston displacement
When the initial displacement of the cylinder is not 0mm, the solver requires a mass block.

9 meses hace | 0

| aceptada

Pregunta


Transient initialization failed to converge using Simscape piston displacement
Good day to you, I'm working on a isothermal liquid model, in which a double acting piston is first extended and later retract...

9 meses hace | 1 respuesta | 0

1

respuesta

Respondida
Pressure problems when controlling a double acting actuator (IL) in Simscape
I solved this problem by replacing the ideal pressure source with a fixed displacement pump, that is able to provide the system ...

9 meses hace | 0

| aceptada

Pregunta


Pressure problems when controlling a double acting actuator (IL) in Simscape
Hello, I am currently working on a simple hydraulic project using isothermal liquid components. What I`m essentially trying to d...

10 meses hace | 1 respuesta | 0

1

respuesta