How to use circshift in Simulink?
It is not really a matrix. I suggest debugging the MATLAB Function first. Provide a Constant vector input, e.g. (1:5), observe t...
3 días hace | 0
| aceptada
Restart signal from workspace in Simulink
Use an Integrator block and enable its "Reset" inport, which can receive your "reset" or "trigger" signal. The input to the In...
13 días hace | 0
| aceptada
I need help in fixing this code as I keep getting errors
No error but warnings. The cause is that N/2 is not an integer because in your case, N is 1001. It is surprise that in the exa...
18 días hace | 0
Matlab gave me a right value for PA< PB< PZa ,PZb, Pzc but they said the wrong thing about conclusion, they said " does not equl. However, it will equal
It is not robust to use == operator to compare two floating-point data. Search for "floating point data equal comparison" and yo...
25 días hace | 0
Fliping Mux in Matlab code
set_param(BlockPath,'Orientation','left')
28 días hace | 0
| aceptada
check Matlab tlbxs availabe and license
featureStr={'MATLAB','Simulink'} index = cellfun(@(f) license('test', f), featureStr) availableFeatures = featureStr(logical(i...
alrededor de 1 mes hace | 0
Branched Merge Block Check - How do I prevent this warning ?
Do you have cascaded Merge blocks? Do any of the incoming signals to Merge1 and Merge2 come from a Merge block? Or the output of...
alrededor de 1 mes hace | 0
Matlab function in Simulink exhibiting slow reaction time
I must know this. 1700 seconds is roughly 1/50 of the simulation time (24 hours). It is the default setting. It must mean that y...
alrededor de 1 mes hace | 0
| aceptada
How to make custom library in Simulink available to other users and in different versions?
If you have a newer version of MATLAB (e.g. R24b), you can save/export a Simulink model or library as older version (e.g. R23b),...
alrededor de 1 mes hace | 0
how can I array the external inputs for code generation in Simulink embedded coder?
For the array case, you just need to specify the size of that Inport block. Keep in mind that you can't comibne multiple inputs ...
alrededor de 1 mes hace | 0
Table.Properties.VariableNames will add ... to long Variable Names
I think the OP was referring to the three dots in the image in the header row. It is a display, @Alexander Szambor. If you drag...
alrededor de 1 mes hace | 1
How to call columns from table when heading names are variable dependent
use data.(MaxColumn). This is similar to dynamic field names like below. a.FirstColumn=1; ColumnName='FirstColumn' a.(ColumnN...
alrededor de 1 mes hace | 0
| aceptada
I am getting error for configurable subsystem in R2024b
"Configurable subsystem" is in pretty old versions of Simulink. It sounds like that in R2024b, it is definitely no longer suppor...
alrededor de 1 mes hace | 1
How to read out value from simout object
You need to click that signal line, right click, select properties, and then give it a name and log the signal. Once done that, ...
alrededor de 1 mes hace | 0
| aceptada
Delay - bus as initial condition and bus propagation
I am intested in this question so I made an example. According to the document, 'The initial condition x0 port accepts nonvirtu...
alrededor de 2 meses hace | 0
Simulation manager with initFcn
'InitFcn' is executed before the simulation starts, that is probably the reason that your parameter values set in the multiple s...
alrededor de 2 meses hace | 0
What is the Matlab code that connects a variable to a Slider Switch Block?
The 'binding' needs to be a block in the model. If that block uses 'A' as a parameter and that parameter is selected to be bound...
alrededor de 2 meses hace | 1
[Linux] Error in MatlabWindow after upgrading Ubuntu from 20.04 to 22.04
According to this, up to Ubuntu 18.04 LTS is supported by MATLAB R2018b. https://www.mathworks.com/content/dam/mathworks/mathwo...
alrededor de 2 meses hace | 0
Force default datatype to single in undefined Simulink blocks
'DefaultUnderspecifiedDataType' is not the same as 'Default DataType'. Your setting only applies to the Constant block because i...
alrededor de 2 meses hace | 0
| aceptada
How do I get the relative error between 2 signals in Simulink?
Assume x and y are the two signals, you are doing abs((x-y)/x) or abs((x-y)/y), when x or y is close to zero, it will cause di...
alrededor de 2 meses hace | 1
| aceptada
Tally Instances of Negative Numbers in an Array (for loop)
A=load() returns A as a structure, not a typical matrix. If you make A an matrix, this code would work if you make the following...
alrededor de 2 meses hace | 0
isnan to conver nan to zero in a table
T is an object of the class "table". You can't apply isnan() on it directly. Try the 'TreatAsMissing' option of the readtable() ...
alrededor de 2 meses hace | 0
Is there a way to extract a list from "PV Array.ModuleName.Enum" to view the solar module data more efficiently?
Should be BlockDialogParameters.ModuleName.Enum or getfield(BlockDialogParameters.ModuleName,'Enum')
alrededor de 2 meses hace | 0
Plot RGB triplets from a matrix as markers 'o'
Use 'color' to specify color in plot() x = linspace(0,10,10); y = linspace(0,10,10); xlabel('X-axis'); ylabel('Y-axis'); ax...
alrededor de 2 meses hace | 0
What is the max number of digits allowed for a base 2 number?
The default data type in MATLAB is "double", which means 64 bits. When used to represent a base 2 number, its maximum value is 2...
2 meses hace | 0
How to set Simulink block parameters using an absolute model path
The "absolute model path" of a block starts with the name of the model, not including the file folder where the model file is st...
2 meses hace | 0
| aceptada
How to output text to Command Window if signal changes from 0 to 1 in Simulink
You might want to do that, but MATLAB and Simulink are quite different. I don't think you can do that because disp() or fprint...
2 meses hace | 0
I can't download Matlab R2022a release or earlier release
I can see many versions on this link. https://www.mathworks.com/downloads/
2 meses hace | 0
How to change const variable during simulink runtime
While the simulation is running, if you double click the Constant block, change its value from one numeric value to another (e.g...
2 meses hace | 0
Initial condition from external source for discrete integration diuring runtime
The value of "mec_init_pos" could be constant or dynamic, but in this case, only its value at the begining of the simulation (e....
3 meses hace | 1