Pregunta


Why does my Simulink model take so long to run?
I am working with a large but new-to-me Simulink model in MatLab 2017A. This model takes over 26 minutes to run, which makes it...

alrededor de 6 años hace | 2 respuestas | 0

2

respuestas

Pregunta


Possible bug in Negating a Boolean Input to a Stateflow
I am building a model in 2017A, and spent a few days hunting down what I thought was a logic bug in my code, but now looks like ...

más de 6 años hace | 1 respuesta | 0

1

respuesta

Pregunta


Find Library links which could not be resolved
Whenever I open a large model, I get a warning that a linked model can only be found in a case-insensitive match. I don't recog...

alrededor de 7 años hace | 0 respuestas | 0

0

respuestas

Pregunta


How to disable warning for Stateflow action language
I am working on a script which temporarily adds content to a Simulink model, builds the model, then removes the new content. I ...

casi 8 años hace | 1 respuesta | 0

1

respuesta

Pregunta


M-script to determine if user has administrator rights
I am seeing an issue where my script crashes for some users on some machines, because that user does not have administrative rig...

más de 8 años hace | 3 respuestas | 0

3

respuestas

Respondida
How to search all parameters of all blocks in a model
I just found an answer to my own question: "find_system('RegExp', 'on', 'BlockDialogParams', '{my data type}')" finds any Sim...

más de 8 años hace | 0

| aceptada

Pregunta


How to search all parameters of all blocks in a model
I need my script to find all of the references to a particular data type within a Simulink model. I understand how I could find...

más de 8 años hace | 1 respuesta | 0

1

respuesta

Respondida
I have just downloaded an updated fixed-license file. How do I activate it?
MathWorks confirmed that my "Activate Software" procedure actually was working. The problems is that the new software license f...

alrededor de 9 años hace | 1

Pregunta


I have just downloaded an updated fixed-license file. How do I activate it?
I recently started to get a message whenever starting MatLab, saying my license will expire in ## days (initially 60 days, decre...

alrededor de 9 años hace | 3 respuestas | 0

3

respuestas

Pregunta


Is it possible to use a ConnectionCallback without an External Script?
I would like to enable a callback function for a port connection change, in a block within a blockset I am developing for severa...

casi 10 años hace | 0 respuestas | 0

0

respuestas

Pregunta


How can a Script Read a resolved Data Type String?
I need to have my m-script read the data types of several blocks and labeled signals in a Simulink model, immediately after the ...

alrededor de 11 años hace | 1 respuesta | 0

1

respuesta

Pregunta


Determine if script will crash due to Read-Only model workspace
I have a script which can be called either from a block's mask parameters being changed, or from the same block's "copyfcn" call...

más de 11 años hace | 0 respuestas | 0

0

respuestas

Pregunta


Using just the Get of a GetSet signal (or at least supressing the Set initialization)
I have some code which worked in MatLab 2008b, defining mpt.Signal objects for my Simulink model's inputs and then auto-coding m...

alrededor de 12 años hace | 1 respuesta | 0

1

respuesta

Respondida
Find name of MPT signal of input line
Unfortunately, that only finds lines which are manually named with the signal name. I need to find where the signal goes from t...

alrededor de 12 años hace | 0

Pregunta


Find name of MPT signal of input line
I have a large Simulink model which includes many signals associated with mpt.Signal objects in the base workspace (so that thes...

alrededor de 12 años hace | 2 respuestas | 0

2

respuestas

Respondida
Programatically test-run a model before RTW build
I had been trying to figure out when it was done compiling and pause until that time. But then I saw the edits in TAB's first a...

más de 12 años hace | 0

Respondida
Programatically test-run a model before RTW build
Thank you both for your answers! I think I can now more clearly define the problem I am having with my model. If I type in my ...

más de 12 años hace | 0

Pregunta


Programatically test-run a model before RTW build
I am working on a script which sets up a few interfaces in a model and then builds it. Normally before running this script, I r...

más de 12 años hace | 5 respuestas | 0

5

respuestas

Pregunta


Mask dialog box too small, adds verticle scrollbars
This is a small display issue, but it is annoying. I am developing a custom blockset, using masked subsystems for some of the b...

casi 13 años hace | 1 respuesta | 0

1

respuesta