Default Deactivation of "Limit data points to last" in Simulink Viewer
4 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Martin
el 25 de Nov. de 2013
Respondida: Zack Peters
el 25 de Nov. de 2013
If you add a viewer to a line, the data point limitation is activated by default with a value of 7500. Is it possible to deactivate this limitation for all new viewers? Can this be done as a default setting only on model level or as general default setting?
0 comentarios
Respuesta aceptada
Zack Peters
el 25 de Nov. de 2013
Hi Martin,
Currently there is no way to set this on a model level or at the Simulink preferences level. One thing you may try is to create a Scope library block and change the setting in there. From there you can open that library and drop that block (and not the default simulink scope) into new models.
~Zack
0 comentarios
Más respuestas (0)