I am attempting to complete the HDL Verifier Tutorial "Verify Raised Cosine Filter Design With Generated Simulink Test Bench. I reach the step "Select HDL Modules for Cosimulation (Simulink). I follow tutortial directions and then press next. The wizard then attempts to launch HDL Simulator but times out/
In the MATLAB Command Window I get the following warnings: Warning: ModelSim Altera edition is not supported by HDL Verifier
In log file I get: Error: (vsim-FLI-3155) The FLI is not enabled in this version of ModelSim.
When I try from Simulink I get: Error reported by S-function 'shdlcosim' in 'viterbi_modelsim/viterbi_hdl/S-Function': Failed to connect to server. Make sure the loaded HDL simulator library is using shared memory
I have found others that appear to have a similar issue, and the answer has been simply that Altera Modelsim is not supported by HDL Verifier.
My question is if there is any work around.
Thanks
0 comentarios
Respuesta aceptada
Tao Jia
el 7 de Mayo de 2014
Unfortunately, there is no workaround. The best way is to use one of the ModelSim versions supported by HDL Verifier, e.g., ModelSim PE.