Simulink Compiled Code NaN

1 visualización (últimos 30 días)
B. J.
B. J. el 10 de Ag. de 2011
Hello,
I have a theoretical question I am unable to test right now...if I compile some simulink code down, and pass some "bad" data into it, what type of error handling would I receive? For example, if my simulink code was simply x (input)
y = 3*x(1)/x(2)
And I managed to have x(1) = NaN...or worse, x(2) = 0, what would my compiled code throw me?
thanks, B.

Respuesta aceptada

Mike Hosea
Mike Hosea el 10 de Ag. de 2011
Look under
Simulation-->Configuration Parameters-->Diagnostics-->Data Validity
There is a setting for "Inf or NaN block output". You can set it to "none", "warning", or "error". That's in simulation, of course. If you build code for some standalone target, e.g. exe, then you will not get an error or a warning for this condition, just Infs or NaNs, as the case may be. -- Mike

Más respuestas (1)

B. J.
B. J. el 10 de Ag. de 2011
A follow on thought...can I somehow use the model advisor to specify how I want it to handle these errors?