I am debugging code using the serial port. If I exit the debug session normally via <shift>F5, I cannot reopen the serial port upon restarting a new debug session. I get the error listed at the bottome of this post. I have to shutdown matlab completely to clear everything.
I can understand why the port is still open (it was not closed upon exiting debug), however I need a way to "clear" it and reopen it after the next debug session.
I issue the 'delete(instrfindall)' at the start of the program but this does not work.
Thanks for any ideas, Fritz
==============================================
??? Error using ==> serial.fopen at 72
Cannot connect to the COM5 port. Possible reasons are another
application is connected to the port or the port does not exist.
Error in ==> spectrometer_monitor at 39
fopen(s);
  2 comentarios
Ariel
Ariel el 27 de Ag. de 2013
Hello Fritz.
My name is Ariel and I'm dealing the same problem. have you found solution?
Thank you
Ariel
Ivan Peric
Ivan Peric el 23 de En. de 2018
You can try this: -right click myCoumputer -properties -device manager -serial -ports -right click your port -disable -enable

Iniciar sesión para comentar.

Respuestas (1)

Adam
Adam el 16 de Ag. de 2011
instrreset
is your friend!
Clear the serial object then issue an instrreset.
  4 comentarios
Adam
Adam el 16 de Ag. de 2011
From MATLAB documentation on delete:
"Remarks