Error:Each physical network must be connected to exactly one Solver Configuration block. There is no Solver Configuration block connected to Physical Network with the following blocks
538 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
I had connected a solver configuration block in my model but these error is popping up when i connect a "current-Voltage simscape interface" block in my model.Kindly guide me in solving this problem. Thanking you, Saideep.
0 comentarios
Respuestas (4)
Yogeshwar Bala
el 6 de Oct. de 2018
Connect an "Electrical Reference" block to your ground line and add a Solver Configuration block with default value of f(x) = 0 to it.
5 comentarios
Reginald Ogu
el 17 de Mzo. de 2023
Please how can I add a Solver Configuration block to my Simscape model?
Huang YanMing
el 4 de Mzo. de 2024
To add a "Solver Configuration"
Go to library browser and find it in the below folder
Simscape>Utilities
Behnam Mohammad
el 15 de En. de 2020
What happens when you have multiple subsystems and each subsystem has an individual solver?
0 comentarios
ever steeven nevarez cedeño
el 31 de Ag. de 2021
tengo un problema similar pero al reves el problema es cuando lo pongo
1 comentario
Joel Van Sickel
el 10 de Jun. de 2024
This specific problem happens from the interface block. Those blocks are used to decouple simscape networks and if you look under the hood, you will see they are connected by simulink wires, not simscape wires. This means that if you use one, you will now have an additional simscape network, so you will need to add an additional simscape configuration block to the side of the network that doesn't already have one. Or you will need to add it to both sides if neither side has one.
0 comentarios
Ver también
Categorías
Más información sobre Troubleshooting en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!