Double Circuit Line Modelling

6 visualizaciones (últimos 30 días)
vvd03
vvd03 el 20 de Nov. de 2014
Comentada: vvd03 el 23 de Nov. de 2014
Hi,
I modelling double circuit line with Distributed Parameter Line. I have positive and zero sequence impedance of line and mutual impedance of lines. How to enter this data to block parameters? I think this block six=phase, but I don't know how need to form matrices of line parameters. Do you have examples?

Respuesta aceptada

Sebastian Castro
Sebastian Castro el 20 de Nov. de 2014
Hello,
You only have to use a matrix if the line is asymmetric.
For a symmetrical line, you can either specify the N-by-N matrix or the sequence parameters. For a two-phase or three-phase continuously transposed line, you can enter the positive and zero-sequence resistances [r1 r0] . For a symmetrical six-phase line you can enter the sequence parameters plus the zero-sequence mutual resistance [r1 r0 r0m].
If your line is asymmetric, you can double-click the Powergui block in your model and select Compute RLC Line Parameters . This can help you get matrices and push them into a block, although I think the information you have is more compatible with the [r1 r0 r0m] block entries.
Best,
Sebastian
  1 comentario
vvd03
vvd03 el 23 de Nov. de 2014
Thanks for answer!
I did so, but calcCurrent not equal ControlCurrent. In standard examples of Simulink I find example of calculation parameters of Double-Circuit Line 315 kV. Result matrice of resistance have size 6x6, result matrice of sequence parameters have size 1x5. When I enter this parameters in block I have error "Attempted to access z(1,6); index out of bounds because size(z)=[1,5]".

Iniciar sesión para comentar.