An error when I run with model reference
3 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
I built a model of Wind farm, and the wind turbines are used by referenced models that I built and converted. Then I run this wind farm model. There is an error I don't understand.
Caused by:
- Invalid run-time parameter registration in S-function 'sfun_spssw_discc' in model 'WF100MW'. An S-function can register run-time parameters only if the S-function is being inlined. To be able to reference the model 'WF100MW', the S-function 'sfun_spssw_discc' needs to set the option SS_OPTION_USE_TLC_WITH_ACCELERATOR and it needs to have a TLC file.
1 comentario
Walter Roberson
el 3 de Feb. de 2022
Try turning Acceration to Normal; https://www.mathworks.com/help/sldo/ug/accelerating-model-simulations-during-optimization.html
Respuestas (1)
Saurabh
el 20 de Nov. de 2024
To address this issue, try using 'powergui.' Navigate to preferences and enable the option called 'Use TLC file when in Accelerator Simulation Mode and for code generation.'
The same information can be found here:
- https://www.mathworks.com/help/sps/powersys/ref/powergui.html#mw_081370b9-45b5-4a1f-9710-94f3835bf2cc
- https://www.mathworks.com/help/simulink/sfg/ss_option_use_tlc_with_accelerator.html
I hope this helps.
0 comentarios