Problem converting and displaying Dicom(ultrasonics) image for Matrix

1 visualización (últimos 30 días)
I have a project to read a DICOM file and determine if it is a DICOM file or not. Then read the content of the file and convert it to Matrix and then display it as an image. But unfortunately the picture always appears like this for me
But when I view the image in another program, it appears in its true form
elseif strcmp(Group,'7FE0')
if strcmp(Element,'0010')
if dicom_data{7,5}==16
dcmImage = uint16(fread(fID,[dicom_data{5,5} dicom_data{6,5}],'uint16')');
dicom_data{10,5} = dcmImage;
else
dcmImage = uint16(fread(fID,[dicom_data{5,5} dicom_data{6,5}],'uint8')');
dicom_data{10,5} = dcmImage;
end
else
fseek(fID,ValueLength,0);
end
else
if(ftell(fID)==DateiEnde)
break
end
fseek(fID,ValueLength,0);
end
end
imshow(dicom_data,[0 2^dicom_data{9,5}])
This is the data it reads from the DICOM file
ans =
10×5 cell array
{'TransferSyntax' } {'2' } {'10' } {'UI'} {'1.2.840.10008.1…'}
{'PatientName' } {'10' } {'10' } {'PN'} {'no patient' }
{'SamplesPerPixel'} {'28' } {'2' } {'US'} {[ 3]}
{'NumberOfFrames' } {'28' } {'8' } {'IS'} { 2×1 char }
{'Rows' } {'28' } {'10' } {'US'} {[ 512]}
{'Cols' } {'28' } {'11' } {'US'} {[ 512]}
{'BitsAllocated' } {'28' } {'100'} {'US'} {[ 8]}
{'BitsStored' } {'28' } {'101'} {'US'} {[ 8]}
{'HighBit' } {'28' } {'102'} {'US'} {[ 7]}
{'PixelData' } {'7FE0'} {'10' } {'OB'} {512×512 uint16 }
  7 comentarios
Khaled Al Hamidi
Khaled Al Hamidi el 29 de Mayo de 2022
Thank you
I found the problem related to the size of the array, I changed it to another size and the problem was solved
from:
dcmImage = uint8(fread(fID,[dicom_data{5,5} dicom_data{6,5}],'uint8')');
to:
dcmImage = uint8(fread(fID,[1536 512],'uint8')');
but I got a non-rectangular image
Walter Roberson
Walter Roberson el 29 de Mayo de 2022
Experiment with reversing the size numbers in the fread()

Iniciar sesión para comentar.

Respuestas (1)

aditi bagora
aditi bagora el 10 de Oct. de 2023
Hello Khaled,
I understand you want to read a DICOM (ultrasonics) file and extract the values from its metadata. It seems that you are currently using the "fread()" and "fseek()" functions to read the binary file. However, you are encountering issues when reading the pixel data, which could be due to a mismatch in reading the binary data in a particular format or inconsistent data in the file.
To overcome these issues, you can manually try reading the binary file using "fread()" and "fseek()", you can try using the "dicomread()" and "dicominfo()" functions. These functions are specifically designed to read pixel data and metadata from DICOM files, ensuring compatibility and accurate extraction.
To read the pixel data and dicom data, you can refer to the following example code:
pixel_data = dicomread(filename); % read pixel data
imshow(pixel_data);
dicom_data = dicominfo(filename); % To read the DICOM metadata.
Please refer to the following links for more information:
Hope this helps!
Regards,
Aditi
  1 comentario
Walter Roberson
Walter Roberson el 10 de Oct. de 2023
The purpose of the project was to learn how to use low-level facilities to work with files.