Defining pmsm parameters for delta configuration
    6 visualizaciones (últimos 30 días)
  
       Mostrar comentarios más antiguos
    
    Jordan  Graham
 el 6 de Jun. de 2022
  
    
    
    
    
    Respondida: Dr Narayanaswamy P R Iyer
      
 el 6 de Jun. de 2022
            I am trying to define the parameters for a PMSM in delta configuration in SimScape. By considering the layout diagram for the wye wound configuration in the help window related to the block I can see that the phase-phase terminal resistance and inductance specified on the datasheet should be divided by 2 to define the 'per phase' resistance and axis inductances for the pmsm. 
I am not so clear on defining these parameters for a delta wound configuration as there is no layout diagram for this, does the winding configuration influence how these parameters are defined? From looking at other delta wound layout diagrams I would be leaning towards not dividing these parameters by 2. 
0 comentarios
Respuestas (1)
  Dr Narayanaswamy P R Iyer
      
 el 6 de Jun. de 2022
        The resistance and inductance values must be multiplied by 2/3 to get the per phase values for delta configuration. Thanks. DR. N P R IYER.