Closed loop discrete PI controller
7 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Pranav Pillai
el 25 de Ag. de 2022
Comentada: Joel Van Sickel
el 9 de Sept. de 2022
how to find integral and proportional constants.how can i interface it with a PWM and switch input to get desired op.
3 comentarios
Sam Chak
el 3 de Sept. de 2022
Could you provide the transfer function of the boost converter? It helps to determine the suitable values for the PI gains.
Respuesta aceptada
Joel Van Sickel
el 6 de Sept. de 2022
Hello,
please use the references on this page to dive deeper into designing closed loop control for boost converters.
Regards,
Joel
0 comentarios
Más respuestas (1)
Pranav Pillai
el 9 de Sept. de 2022
1 comentario
Joel Van Sickel
el 9 de Sept. de 2022
Hello Pranav, if you use average mode converter models, you can do it fairly simply using the controls toolboxed and the model linearizer app.
If you want to keep switching involved, you'll need to do a frequency reponse
Here is the basics for frequency response estimation.
One other alternative is since it's a boost converter, you can derive the 2nd order transfer function of the system, and close the loop with your PI controller using matlab commands or do it analytically. Wikipedia has the equivalent closed loop system for controller and plant defined as transfer functions available publicly, but getting the 2nd order transfer function for a boost converter is mostly in conference and journal papers.