supply variable efficiency map to a hydraulic pump

1 visualización (últimos 30 días)
Vivek
Vivek el 27 de Feb. de 2015
Respondida: Yifeng Tang el 16 de Jun. de 2022
Hi All,
How can I input an efficiency map instead of a fixed value parameter for the fixed-displacement hydraulic pump model in simhydraulics?
Any ideas?

Respuestas (1)

Yifeng Tang
Yifeng Tang el 16 de Jun. de 2022
In newer versions of Simscape Fluids, the fixed-displacement pumps allow lookup tables as inputs to specify the efficiency as a function of pressure gain and rpm.
If those are not available to you, the way to implement this manually is via lookup table outside ideal source blocks. A diagram like below can be a starting point. It only cover the volumetric efficiency part and requires RPM as a signal input.
If you want to couple it with the mechanical domain, as in the fixed-displacement pump block, you may add a torque source and a velocity sensor for that purposes. The input to the torque source will be calculated from the delta_P and mechanical efficiency lookup table. The output from the velocity sensor will be sent to the "pump".

Categorías

Más información sobre Simscape Fluids en Help Center y File Exchange.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!