supply variable efficiency map to a hydraulic pump
    4 visualizaciones (últimos 30 días)
  
       Mostrar comentarios más antiguos
    
Hi All,
How can I input an efficiency map instead of a fixed value parameter for the fixed-displacement hydraulic pump model in simhydraulics?
Any ideas?
1 comentario
  Junfei Tang
 el 4 de Feb. de 2016
				You can have a look at this. I guess it might be similar to your issue:  http://www.mathworks.com/matlabcentral/answers/44515#answer_208604
Respuestas (1)
  Yifeng Tang
    
 el 16 de Jun. de 2022
        In newer versions of Simscape Fluids, the fixed-displacement pumps allow lookup tables as inputs to specify the efficiency as a function of pressure gain and rpm.  
If those are not available to you, the way to implement this manually is via lookup table outside ideal source blocks.  A diagram like below can be a starting point.  It only cover the volumetric efficiency part and requires RPM as a signal input.

If you want to couple it with the mechanical domain, as in the fixed-displacement pump block, you may add a torque source and a velocity sensor for that purposes.  The input to the torque source will be calculated from the delta_P and mechanical efficiency lookup table.  The output from the velocity sensor will be sent to the "pump".
0 comentarios