about nonvirtual subsystem,how to solve it
Mostrar comentarios más antiguos
Connections of the Physical Network cross nonvirtual boundaries. If any blocks in a Physical Network are within a nonvirtual subsystem, then all blocks of that network must be in the same nonvirtual subsystem. Either move affected blocks out of the nonvirtual subsystem, move network blocks into exactly one nonvirtual subsystem, or reconfigure affected nonvirtual subsystems to be virtual subsystems.
3 comentarios
Saif Sayed
el 17 de Ag. de 2016
Hi, I encountered the same problem. Were you able to solve it?
Ammon McCarthy
el 16 de Abr. de 2020
Hi, I also have this problem. Was this taken care of?
Thirumala
el 4 de Abr. de 2025
Any solution?
Respuestas (1)
MULI
el 15 de Abr. de 2025
0 votos
The error you are observing "Connections of the Physical Network cross nonvirtual boundaries..." is a known limitation which can be found in the below MathWorks documentation link:
Instead, you can try one of the following solutions:
- Make all related subsystems virtual (Right-click the subsystem → Subsystem Parameters → Uncheck "Treat as atomic unit")
- Move all physically connected blocks into a single nonvirtual subsystem