Observer Port Links are gone

2 visualizaciones (últimos 30 días)
Jung Soon Jang
Jung Soon Jang el 4 de Mayo de 2023
Comentada: Rui Chen el 24 de Mayo de 2023
I created an Observer in a Simulink test harness and mapped signals to Observer Ports. Then I saved and closed the test harness and the Observer. When I reopened the test harness from Test Manager and clicked "Manage Observer" in the Observer model, previously linked signals to the Obersver Ports are not there anymore. Note that the Simulink test harness model is not detached from the main model (i.e., internally saved inside the main model). The links of the Observer Ports are preserved when created from a detached (or separated) harness model. Any insights would be appreciated.

Respuestas (1)

Krishna Balasubramanian
Krishna Balasubramanian el 18 de Mayo de 2023
Hi Jung Soon,
Apologies for the delay in answering this question. This is a known issue and a fix is available for R2022b and beyond. If you are on an earlier version, you can work around this issue by using externally saved test harnesses.
Regards,
Krishna
  1 comentario
Rui Chen
Rui Chen el 24 de Mayo de 2023
Hi Jung Soon,
Here's the bug report page for this issue:
Thanks,
Rui