Input data dependency violation due to action subsystems. See Subsystem Examples in the Simulink library for valid and invalid examples of action subsystems

35 visualizaciones (últimos 30 días)
I am using the MTPA Reference block from the 'Motor Control Blockset'. When I connect the 'MTPA Reference block' to my current controller, I get this error: "Input data dependency violation due to action subsystems. See Subsystem Examples in the Simulink library for valid and invalid examples of action subsystems"
I have attached my model and pictures here, I have been going at it for the past few days but I am not able to solve this error. Any and all help on this is very very much appreciated.
Thanks in advance!

Respuesta aceptada

Darshan Pandit
Darshan Pandit el 31 de Mayo de 2023
Hi aditya,
You're trying to simulate continuous time plant with discrete time control system. The sensor models should do the conversion.
Anyway, for the issue at hand, pl add rate transition or delay blocks in your feedback loop (bottom red line) as well as the first output of MechSensor subsystem. Also check 'use local solver' box in the solver configuration.
Hopet his helps.

Más respuestas (0)

Categorías

Más información sobre Motor Parameter Estimation and Plant Modeling en Help Center y File Exchange.

Productos


Versión

R2022b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by