unable to resolve cooling plate error
2 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
SUDEEP SINGH RAWAT
el 26 de Jul. de 2023
Respondida: Joel Van Sickel
el 28 de Jul. de 2023
hi there,
i am modelling a battery module with cooling plate. while running the simulation, i am getting this error;
"Error compiling Simscape network for model molicell_module_with_cooling_plate.
Caused by:
Connection 'connect(NewModule.BottomExtClnt,Parallel_Channels.Side1)' is found to be connecting arrays of nodes of inconsistent sizes: '1x14' and '1x196'. The arguments in a connection must be of the same size."
kindly help in resolving this error. Thanks
3 comentarios
Respuesta aceptada
Joel Van Sickel
el 28 de Jul. de 2023
I think you need to set your number of nodes to 14 and not 14x14 for the cooling plate. If that doesn't solve it, please share your model instead of screen shots to get further assistance.