I want to design the loss calculation model of three phase inverter and loss calculation of the motor using the FEM Parameterized PMSM
4 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
I am designing the three phase inverter having both the loss calculation of the inverter and motor.
While simulating i am getting an error.
Error compiling Simscape network for model PMSM_MOSFET_2.
Caused by:
- Frequency and time simulation is not applicable because sinusoidal expressions are not used by any other equations and have been eliminated.
- Check variable intrm_sf_mf__2.
- Check variable intrm_sf_mf__3.
0 comentarios
Respuestas (2)
Sabin
el 6 de Feb. de 2024
Frequency-and-time equation formulation is intended for systems with a single nominal frequency. It is not possible to simulate switching devices such as MOSFETs. When designing the electric drive and power inverter you should set the 'Equation formulation' to 'Time' in the Solver Configuration block.
Ver también
Categorías
Más información sobre Choose and Parameterize Blocks en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!