Simulating for U channel cooling system using own battery pack.
5 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Hitesh Kumar Nath
el 7 de Feb. de 2024
Error:Error compiling Simscape network for model BatteryWithCollingPlate.
Caused by:
Connection 'connect(Module1.BottomExtClnt,U_shaped_Channels.Side1)' is found to be connecting arrays of nodes of inconsistent sizes: '1x1' and '1x42'. The arguments in a connection must be of the same size.
0 comentarios
Respuesta aceptada
Kautuk Raj
el 14 de Feb. de 2024
Movida: Joel Van Sickel
el 20 de Feb. de 2024
I suggest verifying the the sizes of the ports on both components (Module1.BottomExtClnt and U_shaped_Channels.Side1). As the error message states, to resolve this issue, you need to ensure that the ports being connected have the same size.
You can share your Simulink model BatteryWithCollingPlate here for a better understanding.
1 comentario
Más respuestas (0)