issues on Heat exchanger in simscape 2P-TL

9 visualizaciones (últimos 30 días)
runyi
runyi el 11 de Sept. de 2024
Comentada: Yifeng Tang el 18 de Sept. de 2024
My System-Level Condenser Evaporator (2P-TL) shows an error in my model.
Failed to determine size of heat exchanger from the specified nominal operating condition. Try reducing Nominal rate of heat transfer or increasing Try reducing Nominal rate of heat transfer or increasing Nominal mass flow rate.
There should be a problem with my heat exchanger cross-sectional area settings, but I can't fix it.

Respuestas (1)

runyi
runyi el 12 de Sept. de 2024
Oh,I've solved it!
My heat storage tank temperature is set incorrectly.
  1 comentario
Yifeng Tang
Yifeng Tang el 18 de Sept. de 2024
This error is saying that if the specified heat flow is honored, the outlet temperature of the hot fluid will be lower than the inlet temperature of the cold fluid, which violate the 2nd law of thermal dynamics. It's usually a parameterization error. Things to look for:
  1. Heat flow value and unit
  2. Fluid 1 flow rate, temperature and unit
  3. Fluid 2 flow rate, temperature and unit
  4. Fluid 1 & 2 fluid property block. Note each domain has different default working fluid.

Iniciar sesión para comentar.

Categorías

Más información sobre Fluid Network Interfaces Library en Help Center y File Exchange.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by